Aims: Poly (ADP-ribose) polymerase (PARP) inhibitors (PARPIs) represent a standard of care for the clinical management of high-grade serous ovarian cancer (HGSOC). The recognition of homologous recombination deficiency (HRD) has emerged as a predictive biomarker of response for first-line PARPIs treatment in patients with HGOSC. On the other hand, this test is extremely complex and therefore it is often externalised. Regrettably, the reliability of outsourced HRD testing can be troubled by inconclusive results and high rejection rates. In this methodological study, we assessed the technical feasibility, interassay and interlaboratory reproducibility of in-house HRD testing using three different commercially available next-generation sequencing assays. Methods: A total of n=20 epithelial ovarian cancer samples previously analysed with MyChoice CDx were subjected to HRD retesting using three different platforms in three different major pathology laboratories, that is, SOPHiA DDM HRD Solution, HRD focus and Oncomine homologous recombination repair pathway predesigned panel. Concordance was calculated by Cohen's (dual) and Fleiss (triple) κ coefficients. Results: In-house BRCA1/2 molecular testing yielded a concordance rate >90.0% among all participating centres. HRD scores were successfully calculated by each institution with a concordance rate of 76.5%. Concerning the external gold standard test, the overall percentage of agreement ranged from 80.0% to 90.0% with a positive percentage agreement ranging from 75.0% to 80.0% and a negative percentage agreement ranging from 80.0% to 100%. Conclusions: In-house testing for HRD can be reliably performed with commercially available next-generation sequencing assays. © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions.

Morphological Changes of Anomalous Coronary Arteries From the Aorta During the Cardiac Cycle Assessed by IVUS in Resting Conditions / G.M. Formato, M.L. Agnifili, L. Arzuffi, A. Rosato, V. Ceserani, K.G. Zuniga Olaya, F. Secchi, M. Deamici, M. Conti, F. Auricchio, F. Bedogni, A. Frigiola, M. Lo Rito. - In: CIRCULATION. CARDIOVASCULAR INTERVENTIONS. - ISSN 1941-7632. - (2023 Jan), pp. e012636.1-e012636.8. [Epub ahead of print] [10.1161/CIRCINTERVENTIONS.122.012636]

Morphological Changes of Anomalous Coronary Arteries From the Aorta During the Cardiac Cycle Assessed by IVUS in Resting Conditions

F. Secchi;
2023

Abstract

Aims: Poly (ADP-ribose) polymerase (PARP) inhibitors (PARPIs) represent a standard of care for the clinical management of high-grade serous ovarian cancer (HGSOC). The recognition of homologous recombination deficiency (HRD) has emerged as a predictive biomarker of response for first-line PARPIs treatment in patients with HGOSC. On the other hand, this test is extremely complex and therefore it is often externalised. Regrettably, the reliability of outsourced HRD testing can be troubled by inconclusive results and high rejection rates. In this methodological study, we assessed the technical feasibility, interassay and interlaboratory reproducibility of in-house HRD testing using three different commercially available next-generation sequencing assays. Methods: A total of n=20 epithelial ovarian cancer samples previously analysed with MyChoice CDx were subjected to HRD retesting using three different platforms in three different major pathology laboratories, that is, SOPHiA DDM HRD Solution, HRD focus and Oncomine homologous recombination repair pathway predesigned panel. Concordance was calculated by Cohen's (dual) and Fleiss (triple) κ coefficients. Results: In-house BRCA1/2 molecular testing yielded a concordance rate >90.0% among all participating centres. HRD scores were successfully calculated by each institution with a concordance rate of 76.5%. Concerning the external gold standard test, the overall percentage of agreement ranged from 80.0% to 90.0% with a positive percentage agreement ranging from 75.0% to 80.0% and a negative percentage agreement ranging from 80.0% to 100%. Conclusions: In-house testing for HRD can be reliably performed with commercially available next-generation sequencing assays. © Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions.
coronary vessel anomalies; diastole; heart; ischemia; sudden cardiac death; systole;
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/23 - Chirurgia Cardiaca
gen-2023
apr-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
jcp-2023-208852.full.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 953.88 kB
Formato Adobe PDF
953.88 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/984248
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 1
social impact