Aims Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response. Methods and results Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6-24 months of post-implant. Latest electrically activated site and the distance to LVPS (d(p)) were assessed. Left ventricular end-systolic volume (LVESV) reduction of >= 15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and d(p). Of 111 studied patients [64 +/- 11 years, EF 28 +/- 6%, implant duration 12 +/- 5 months (mean +/- SD), 98% had LBBB, 38% IHD], 67% responded at 10 +/- 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. d(p) was 42 +/- 23 mm [31 +/- 14 mm for responders vs. 63 +/- 24 mm non-responders (P < 0.001)]. Longer d(p) and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. d(p) of 47 mm delineated responders and non-responders (AUC 0.931). Conclusion The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.
Non-invasive three-dimensional electrical activation mapping to predict cardiac resynchronization therapy response: site of latest left ventricular activation relative to pacing site / L. Parreira, A. Tsyganov, E. Artyukhina, K. Vernooy, C. Tondo, P. Adragao, C. Ascione, P. Carmo, S. Carvalho, M. Egger, A. Ferreira, M. Ghossein, M. Holm, V. Kalinin, M. Malakhova, M. Meine, S. Nunes, D. Podolyak, A. Revishvili, A. Shapieva, V. Stepanova, A. van Stipdonk, I. Taymasova, P. Wouters, S. Zubarev, F. Leyva, A. Auricchio, N. Varma. - In: EUROPACE. - ISSN 1099-5129. - 25:4(2023 Mar 01), pp. 1458-1466. [10.1093/europace/euad041]
Non-invasive three-dimensional electrical activation mapping to predict cardiac resynchronization therapy response: site of latest left ventricular activation relative to pacing site
C. Tondo;
2023
Abstract
Aims Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response. Methods and results Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6-24 months of post-implant. Latest electrically activated site and the distance to LVPS (d(p)) were assessed. Left ventricular end-systolic volume (LVESV) reduction of >= 15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and d(p). Of 111 studied patients [64 +/- 11 years, EF 28 +/- 6%, implant duration 12 +/- 5 months (mean +/- SD), 98% had LBBB, 38% IHD], 67% responded at 10 +/- 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. d(p) was 42 +/- 23 mm [31 +/- 14 mm for responders vs. 63 +/- 24 mm non-responders (P < 0.001)]. Longer d(p) and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. d(p) of 47 mm delineated responders and non-responders (AUC 0.931). Conclusion The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.File | Dimensione | Formato | |
---|---|---|---|
s41598-023-29501-3.pdf
accesso aperto
Descrizione: Clinical Research
Tipologia:
Publisher's version/PDF
Dimensione
1.79 MB
Formato
Adobe PDF
|
1.79 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.