Purpose: The aim of this study was to assess the reliability of a 2D dark-blood phase-sensitive late gadolinium enhancement sequence (2D-DBPSLGE) compared with 2D phase-sensitive inversion recovery late gadolinium enhancement sequence (2D-BBPSLGE) in patients with ischemic cardiomyopathy (ICM). Materials and Methods: A total of 73 patients with a clinical history of ICM were prospectively enrolled. The following endpoints were evaluated: (a) comparison of image quality between 2D-BBPS(LGE)and 2D-DBPS(LGE)for differentiation between blood pool-late gadolinium enhancement (LGE), remote myocardium-LGE, and blood pool-remote myocardium; (b) diagnostic accuracy of 2D-DBPS(LGE)compared with gold standard 2D-BBPS(LGE)for the evaluation of infarcted segments; (c) diagnostic accuracy of 2D-DBPS(LGE)for the evaluation of microvascular obstruction (MVO); (d) comparison of transmurality index between 2D-BBPS(LGE)and 2D-DBPSLGE; (e) comparison of papillary muscle hyperenhancement between 2D-BBPS(LGE)and 2D-DBPSLGE; inter-reader agreement for depiction of hyperenhanced segments in both LGE sequences. Data were analyzed using pairedttest, Wilcoxon test, and McNemar test, and eta(2)coefficient and intercorrelation coefficient (ICC). Results: Image quality was superior for 2D-DBPS(LGE)for differentiation of blood pool-LGE (P<0.001). 2D-DBPSLGE, compared with 2D-BBPSLGE, showed a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 96.93%, 99.89%, 99.71%, 98.78, and 99.04%, respectively. Concerning MVO detection, 2D-DBPS(LGE)showed a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 66.67%, 100.00%, 100.00%, 80.95%, and 86.21%, respectively. 2D-DBPS(LGE)underestimated the transmurality (P=0.007) and identified papillary muscle hyperenhancement (P<0.001). Both LGE sequences showed comparable interobserver agreement for the evaluation of infarcted areas (2D-BBPSLGE: ICC 0.99;2D-DBPSLGE: ICC 0.99). Conclusions: Compared with 2D-BBPSLGE, 2D-DBP(SLGE)sequences provide better differentiation between LGE and blood-pool, while underestimating LGE trasmurality and the presence of MVO.

Image Quality and Reliability of a Novel Dark-Blood Late Gadolinium Enhancement Sequence in Ischemic Cardiomyopathy / G. Muscogiuri, M. Gatti, S. Dell'Aversana, A.I. Guaricci, M. Guglielmo, A. Baggiano, D. Andreini, S. Mushtaq, E. Conte, A. Annoni, A. Formenti, M.E. Mancini, P. Gripari, M.A. Janich, M.G. Rabbat, M. Pepi, G. Pontone. - In: JOURNAL OF THORACIC IMAGING. - ISSN 0883-5993. - 35:5(2020 Sep), pp. 326-333. [10.1097/RTI.0000000000000448]

Image Quality and Reliability of a Novel Dark-Blood Late Gadolinium Enhancement Sequence in Ischemic Cardiomyopathy

A. Baggiano;D. Andreini;E. Conte;G. Pontone
Ultimo
2020

Abstract

Purpose: The aim of this study was to assess the reliability of a 2D dark-blood phase-sensitive late gadolinium enhancement sequence (2D-DBPSLGE) compared with 2D phase-sensitive inversion recovery late gadolinium enhancement sequence (2D-BBPSLGE) in patients with ischemic cardiomyopathy (ICM). Materials and Methods: A total of 73 patients with a clinical history of ICM were prospectively enrolled. The following endpoints were evaluated: (a) comparison of image quality between 2D-BBPS(LGE)and 2D-DBPS(LGE)for differentiation between blood pool-late gadolinium enhancement (LGE), remote myocardium-LGE, and blood pool-remote myocardium; (b) diagnostic accuracy of 2D-DBPS(LGE)compared with gold standard 2D-BBPS(LGE)for the evaluation of infarcted segments; (c) diagnostic accuracy of 2D-DBPS(LGE)for the evaluation of microvascular obstruction (MVO); (d) comparison of transmurality index between 2D-BBPS(LGE)and 2D-DBPSLGE; (e) comparison of papillary muscle hyperenhancement between 2D-BBPS(LGE)and 2D-DBPSLGE; inter-reader agreement for depiction of hyperenhanced segments in both LGE sequences. Data were analyzed using pairedttest, Wilcoxon test, and McNemar test, and eta(2)coefficient and intercorrelation coefficient (ICC). Results: Image quality was superior for 2D-DBPS(LGE)for differentiation of blood pool-LGE (P<0.001). 2D-DBPSLGE, compared with 2D-BBPSLGE, showed a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 96.93%, 99.89%, 99.71%, 98.78, and 99.04%, respectively. Concerning MVO detection, 2D-DBPS(LGE)showed a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 66.67%, 100.00%, 100.00%, 80.95%, and 86.21%, respectively. 2D-DBPS(LGE)underestimated the transmurality (P=0.007) and identified papillary muscle hyperenhancement (P<0.001). Both LGE sequences showed comparable interobserver agreement for the evaluation of infarcted areas (2D-BBPSLGE: ICC 0.99;2D-DBPSLGE: ICC 0.99). Conclusions: Compared with 2D-BBPSLGE, 2D-DBP(SLGE)sequences provide better differentiation between LGE and blood-pool, while underestimating LGE trasmurality and the presence of MVO.
English
tissue characterization; dark-blood late gadolinium enhancement; late gadolinium enhancement; ischemic cardiomyopathy
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
Goal 3: Good health and well-being
set-2020
LIPPINCOTT WILLIAMS & WILKINS
35
5
326
333
8
Pubblicato
Periodico con rilevanza internazionale
pubmed
crossref
wos
datacite
Aderisco
info:eu-repo/semantics/article
Image Quality and Reliability of a Novel Dark-Blood Late Gadolinium Enhancement Sequence in Ischemic Cardiomyopathy / G. Muscogiuri, M. Gatti, S. Dell'Aversana, A.I. Guaricci, M. Guglielmo, A. Baggiano, D. Andreini, S. Mushtaq, E. Conte, A. Annoni, A. Formenti, M.E. Mancini, P. Gripari, M.A. Janich, M.G. Rabbat, M. Pepi, G. Pontone. - In: JOURNAL OF THORACIC IMAGING. - ISSN 0883-5993. - 35:5(2020 Sep), pp. 326-333. [10.1097/RTI.0000000000000448]
reserved
Prodotti della ricerca::01 - Articolo su periodico
17
262
Article (author)
Periodico con Impact Factor
G. Muscogiuri, M. Gatti, S. Dell'Aversana, A.I. Guaricci, M. Guglielmo, A. Baggiano, D. Andreini, S. Mushtaq, E. Conte, A. Annoni, A. Formenti, M.E. M...espandi
File in questo prodotto:
File Dimensione Formato  
Image.pdf

accesso riservato

Descrizione: Original Article
Tipologia: Publisher's version/PDF
Dimensione 369.99 kB
Formato Adobe PDF
369.99 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/955380
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
  • OpenAlex ND
social impact