We demonstrated a 19-inches 6U-rack sensing system based on quartz-enhanced photoacoustic spectroscopy for simultaneous detection of methane, nitrous oxide, and ammonia in atmosphere. The system embeds two detection modules, each one equipped with a quantum cascade laser as light source and a spectrophone composed of a T-shaped quartz tuning fork coupled with acoustic resonator tubes. The sensing system results compact, lightweight, and portable, with a computer interface for an easy end-user operation. The calibration was performed in laboratory environment with certified concentrations. Because of the NH3 large and permanent dipole moment, ammonia QEPAS signal was used to model and characterize adsorption/desorption processes, for an accurate and reliable sensor calibration. At 0.1 s signal integration time, detection limits of 28 ppb, 9 ppb, and 6 ppb were obtained for CH4, N2O, and NH3, respectively. Since these detection limits were well below the natural abundance of the three analytes in atmosphere, the sensor was employed to monitor CH4, N2O, and NH3 concentrations in laboratory air.

Measurement of methane, nitrous oxide and ammonia in atmosphere with a compact quartz-enhanced photoacoustic sensor / G. Menduni, A. Zifarelli, E. Kniazeva, S. Dello Russo, A.C. Ranieri, E. Ranieri, P. Patimisco, A. Sampaolo, M. Giglio, F. Manassero, E. Dinuccio, G. Provolo, H. Wu, D. Lei, V. Spagnolo. - In: SENSORS AND ACTUATORS. B, CHEMICAL. - ISSN 0925-4005. - 375:(2023), pp. 132953.1-132953.9. [10.1016/j.snb.2022.132953]

Measurement of methane, nitrous oxide and ammonia in atmosphere with a compact quartz-enhanced photoacoustic sensor

G. Provolo;
2023

Abstract

We demonstrated a 19-inches 6U-rack sensing system based on quartz-enhanced photoacoustic spectroscopy for simultaneous detection of methane, nitrous oxide, and ammonia in atmosphere. The system embeds two detection modules, each one equipped with a quantum cascade laser as light source and a spectrophone composed of a T-shaped quartz tuning fork coupled with acoustic resonator tubes. The sensing system results compact, lightweight, and portable, with a computer interface for an easy end-user operation. The calibration was performed in laboratory environment with certified concentrations. Because of the NH3 large and permanent dipole moment, ammonia QEPAS signal was used to model and characterize adsorption/desorption processes, for an accurate and reliable sensor calibration. At 0.1 s signal integration time, detection limits of 28 ppb, 9 ppb, and 6 ppb were obtained for CH4, N2O, and NH3, respectively. Since these detection limits were well below the natural abundance of the three analytes in atmosphere, the sensor was employed to monitor CH4, N2O, and NH3 concentrations in laboratory air.
Quartz -enhanced photoacoustic spectroscopy; Trace gas sensing; Methane; Nitrous oxide; Ammonia; Multi -gas detection
Settore FIS/01 - Fisica Sperimentale
Settore AGR/10 - Costruzioni Rurali e Territorio Agroforestale
   Photonic Accurate and Portable Sensor Systems Exploiting Photo-Acoustic and Photo-Thermal Based Spectroscopy for Real-Time Outdoor Air Pollution Monitoring
   PASSEPARTOUT
   European Commission
   Horizon 2020 Framework Programme
   101016956

   European Joint Doctorate Programme on Optical Sensing using Advanced Photo-Induced Effects
   OPTAPHI
   European Commission
   Horizon 2020 Framework Programme
   860808
2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0925400522015969-main-1.pdf

accesso riservato

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 4.06 MB
Formato Adobe PDF
4.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/954791
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 21
social impact