Background Automated insulin delivery is a game changer for type 1 diabetes treatment. Objective To describe the benefits of automated insulin delivery in a specific complex setting. Methods We are herein presenting a case of a patient with type 1 diabetes, in which Hybrid Closed Loop (Medtronic Minimed 670G on Auto Mode) was used over a year during automated peritoneal dialysis. The patient was previously on insulin therapy with sensor augmented pump and we switched him to Hybrid Closed Loop shortly before the begin of dialysis. Results Automated insulin delivery produced an increase of time in range (70-180 mg/dl) from 63% to 72%, after 3 months and to 74% after one year. Moreover, no hypoglycemia/hyperglycemia urgencies occurred overall during the year. Conclusions The case detailed here is the first report of Hybrid Closed Loop in a patient on automated peritoneal dialysis and it shows an improvement of time in range with a satisfying safety profile in a fragile, aged patient.

One year of Hybrid Closed Loop on peritoneal dialysis: a case report / A. Rossi, L. Montefusco, I. Pastore, M.E. Lunati, S. Argenti, M. Muratori, E. Chebat, G.V. Zuccotti, M. Gallieni, P. Fiorina. - In: ACTA DIABETOLOGICA. - ISSN 0940-5429. - 59:7(2022 Jul), pp. 985-988. [10.1007/s00592-022-01880-5]

One year of Hybrid Closed Loop on peritoneal dialysis: a case report

A. Rossi;I. Pastore;G.V. Zuccotti;M. Gallieni
Penultimo
;
P. Fiorina
Ultimo
2022

Abstract

Background Automated insulin delivery is a game changer for type 1 diabetes treatment. Objective To describe the benefits of automated insulin delivery in a specific complex setting. Methods We are herein presenting a case of a patient with type 1 diabetes, in which Hybrid Closed Loop (Medtronic Minimed 670G on Auto Mode) was used over a year during automated peritoneal dialysis. The patient was previously on insulin therapy with sensor augmented pump and we switched him to Hybrid Closed Loop shortly before the begin of dialysis. Results Automated insulin delivery produced an increase of time in range (70-180 mg/dl) from 63% to 72%, after 3 months and to 74% after one year. Moreover, no hypoglycemia/hyperglycemia urgencies occurred overall during the year. Conclusions The case detailed here is the first report of Hybrid Closed Loop in a patient on automated peritoneal dialysis and it shows an improvement of time in range with a satisfying safety profile in a fragile, aged patient.
Artificial pancreas; Automated insulin delivery; End stage renal failure; Peritoneal dialysis; Type 1 diabetes
Settore MED/13 - Endocrinologia
lug-2022
30-mar-2022
Article (author)
File in questo prodotto:
File Dimensione Formato  
s00592-022-01880-5.pdf

accesso aperto

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 575.68 kB
Formato Adobe PDF
575.68 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/953016
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact