The paper compares three assessment methods for the measurement of the trunk range of motion (ROM) in flexion-extension movements of subjects suspected of lumbar vertebrae instability (LVI). For five male adults affected by low-back pain and with morpho-dynamic prescription for suspected LVI, ROM was computed: from the analysis of morpho-dynamic radiographs, according to the definition proposed by i) Kapandji and ii) Yang et al.; from the analysis of the flexion-extension movement captured with an optoelectronic acquisition system iii) as the maximum angular stroke in transductors’ displacement, according to a specifically designed custom protocol. Data obtained from optoelectronic acquisitions result comparable with literature values, suggesting the suitability of optoelectronic systems as non-invasive measurement tool for the trunk ROM assessing, to support the physician in the LVI diagnosis.

Preliminary Comparison of Assessment Methods for the Trunk Flexion-Extension Movement in the Lumbar Vertebrae Instability Patient / C. Amici, B. Piovanelli, F. Ragni, R. Buraschi, S. Negrini (LECTURE NOTES IN NETWORKS AND SYSTEMS). - In: Human Interaction, Emerging Technologies and Future Systems V / [a cura di] T. Ahram, R. Taiar. - [s.l] : Springer, 2022. - ISBN 978-3-030-85539-0. - pp. 989-994 (( convegno 5th International Virtual Conference on Human Interaction and Emerging Technologies, IHIET 2021 and 6th International Conference on Human Interaction and Emerging Technologies: Future Systems, IHIET-FS 2021 tenutosi a on line nel 2021 [10.1007/978-3-030-85540-6_126].

Preliminary Comparison of Assessment Methods for the Trunk Flexion-Extension Movement in the Lumbar Vertebrae Instability Patient

S. Negrini
Ultimo
2022

Abstract

The paper compares three assessment methods for the measurement of the trunk range of motion (ROM) in flexion-extension movements of subjects suspected of lumbar vertebrae instability (LVI). For five male adults affected by low-back pain and with morpho-dynamic prescription for suspected LVI, ROM was computed: from the analysis of morpho-dynamic radiographs, according to the definition proposed by i) Kapandji and ii) Yang et al.; from the analysis of the flexion-extension movement captured with an optoelectronic acquisition system iii) as the maximum angular stroke in transductors’ displacement, according to a specifically designed custom protocol. Data obtained from optoelectronic acquisitions result comparable with literature values, suggesting the suitability of optoelectronic systems as non-invasive measurement tool for the trunk ROM assessing, to support the physician in the LVI diagnosis.
No
English
Lumbar vertebrae instability; Measurement comparison; Morpho-dynamic radiographs; Movement analysis; Optoelectronic systems; Range of motion; Trunk flexion-extension
Settore MED/34 - Medicina Fisica e Riabilitativa
Intervento a convegno
Esperti anonimi
Pubblicazione scientifica
Human Interaction, Emerging Technologies and Future Systems V
T. Ahram, R. Taiar
Springer
2022
989
994
6
978-3-030-85539-0
319
Volume a diffusione internazionale
5th International Virtual Conference on Human Interaction and Emerging Technologies, IHIET 2021 and 6th International Conference on Human Interaction and Emerging Technologies: Future Systems, IHIET-FS 2021
on line
2021
manual
Aderisco
C. Amici, B. Piovanelli, F. Ragni, R. Buraschi, S. Negrini
Book Part (author)
reserved
273
Preliminary Comparison of Assessment Methods for the Trunk Flexion-Extension Movement in the Lumbar Vertebrae Instability Patient / C. Amici, B. Piovanelli, F. Ragni, R. Buraschi, S. Negrini (LECTURE NOTES IN NETWORKS AND SYSTEMS). - In: Human Interaction, Emerging Technologies and Future Systems V / [a cura di] T. Ahram, R. Taiar. - [s.l] : Springer, 2022. - ISBN 978-3-030-85539-0. - pp. 989-994 (( convegno 5th International Virtual Conference on Human Interaction and Emerging Technologies, IHIET 2021 and 6th International Conference on Human Interaction and Emerging Technologies: Future Systems, IHIET-FS 2021 tenutosi a on line nel 2021 [10.1007/978-3-030-85540-6_126].
info:eu-repo/semantics/bookPart
5
Prodotti della ricerca::03 - Contributo in volume
File in questo prodotto:
File Dimensione Formato  
978-3-030-85540-6_126.pdf

accesso riservato

Dimensione 478.81 kB
Formato Adobe PDF
478.81 kB Adobe PDF   Visualizza/Apri   Richiedi una copia