Background: Previous studies have suggested that mucosal height is related to the bone level and soft tissue thickness. The purpose of this pilot study was to investigate the ratio between the height and width of the tissues around single implants with a conical connection and platform switching. Methods: All patients receiving single implants (Anyridge®, MegaGen, Gyeongbuk, South Korea) and restored with single crowns, in a three-month period, were included in this study. After a provisionalization of 12 months, precision impressions were taken and stone casts were poured for measurements. For each implant, two values were collected at the buccal site: the mucosal height (MH), calculated from the vestibular shoulder of the implant to the upper gingival margin of the supra-implant tissue; and the mucosal thickness (MT), calculated from the vestibular shoulder of the analogue to the external mucosa point perpendicular to the implant major axis. Mean, standard deviation (SD), and confidence intervals (CI 95%) for MH and MT, as well as their ratios, were calculated. Correlation between MH and MT was assessed by Pearson's correlation coefficient, with significance level set at 0.05. Results: 32 single Anyridge® implants were eligible for this evaluation. The mean MH was 3.44 mm (±1.28), the mean MT was 3.29 (±1.46). The average of the ratio between MH and MT of the supra-implant mucosa was therefore 1:1.19 (±0.55). The relation between MH and MT was statistically significant at p ≤ 0.01 (Pearson two-tailed 95% CI). Conclusions: Our study found a constant relationship between width and height of the peri-implant mucosa. However, our results are different from those of Nozawa et al., who found a ratio of 1:1.5 between height and thickness of the peri-implant tissues. This may be determined by the different sample and follow-up period, as well as by the implants used in our study.

Ratio between height and thickness of the buccal tissues: A pilot study on 32 single implants / D. Farronato, M. Manfredini, F. Mangano, G. Goffredo, M. Colombo, P. Pasini, A. Orsina, M. Farronato. - In: DENTISTRY JOURNAL. - ISSN 2304-6767. - 7:2(2019 Jun), pp. 40.1-40.10. [10.3390/dj7020040]

Ratio between height and thickness of the buccal tissues: A pilot study on 32 single implants

D. Farronato
Primo
;
M. Manfredini
Secondo
;
M. Farronato
Ultimo
2019

Abstract

Background: Previous studies have suggested that mucosal height is related to the bone level and soft tissue thickness. The purpose of this pilot study was to investigate the ratio between the height and width of the tissues around single implants with a conical connection and platform switching. Methods: All patients receiving single implants (Anyridge®, MegaGen, Gyeongbuk, South Korea) and restored with single crowns, in a three-month period, were included in this study. After a provisionalization of 12 months, precision impressions were taken and stone casts were poured for measurements. For each implant, two values were collected at the buccal site: the mucosal height (MH), calculated from the vestibular shoulder of the implant to the upper gingival margin of the supra-implant tissue; and the mucosal thickness (MT), calculated from the vestibular shoulder of the analogue to the external mucosa point perpendicular to the implant major axis. Mean, standard deviation (SD), and confidence intervals (CI 95%) for MH and MT, as well as their ratios, were calculated. Correlation between MH and MT was assessed by Pearson's correlation coefficient, with significance level set at 0.05. Results: 32 single Anyridge® implants were eligible for this evaluation. The mean MH was 3.44 mm (±1.28), the mean MT was 3.29 (±1.46). The average of the ratio between MH and MT of the supra-implant mucosa was therefore 1:1.19 (±0.55). The relation between MH and MT was statistically significant at p ≤ 0.01 (Pearson two-tailed 95% CI). Conclusions: Our study found a constant relationship between width and height of the peri-implant mucosa. However, our results are different from those of Nozawa et al., who found a ratio of 1:1.5 between height and thickness of the peri-implant tissues. This may be determined by the different sample and follow-up period, as well as by the implants used in our study.
Aesthetics; Conical implant-abutment connection; Implants; Platform switching; Success; Tissue height; Tissue thickness;
Settore MED/28 - Malattie Odontostomatologiche
giu-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
dentistry-07-00040-v2.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/951400
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact