Background: The purpose in the present study was to compare clinical and radiological outcomes of patients who had undergone a mobile-bearing unicompartmental knee arthroplasty (UKA) with either titanium niobium nitride (TiNbN) alloy implants or with fixed-bearing oxidized zirconium alloy implants. Methods: The records of two consecutive cohorts for a total of 86 hypoallergenic implants were prospectively analyzed. The first cohort consisted of 49 consecutive implantations of the hypoallergenic UKA Journey Uni Oxinium (Ox Group), while the second consisted of 37 consecutive series of UKA Oxford (TiNbN Group). All patients were evaluated by two independent surgeons who were not involved in the index surgery. The clinical evaluation consisted of evaluating each patient’s Oxford Knee Score and Knee Society Score day before surgery (T0), and with two consecutive follow-ups at T1 (minimum follow-up 9 months) and T2 (minimum follow-up 24 months). Results: The two groups were homogeneous in all preoperative values, except Body Mass Index (BMI) and duration of final follow-up [both statistically higher (p < 0.05) in the TiNbN group]. Both groups showed a clinically significant improvement for all scores at final follow-up (p < 0.05). The only differences between the two groups involved a higher pre-operative Oxford Score in TiNbN group (p = 0.031), and different tibial and femoral angles at the final follow-up. Conclusions: Both TiNbN and Oxinium UKA procedures enabled patients from good to excellent clinical and radiographic outcomes after the final follow-up, regardless of the age, gender, BMI bearing type, and implant size. Level of evidence: Level II: Comparative study.
Similar clinical and radiographic outcomes after two different hypoallergenic medial unicompartmental knee in patients with metal allergy / R. D'Ambrosi, N. Ursino, I. Mariani, K. Corona, F.M. Anghilieri, E. Franchi, L. Monti. - In: EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY. - ISSN 1432-1068. - (2022), pp. 1-14. [Epub ahead of print] [10.1007/s00590-022-03295-y]
Similar clinical and radiographic outcomes after two different hypoallergenic medial unicompartmental knee in patients with metal allergy
R. D'Ambrosi
Primo
;I. Mariani;F.M. Anghilieri;
2022
Abstract
Background: The purpose in the present study was to compare clinical and radiological outcomes of patients who had undergone a mobile-bearing unicompartmental knee arthroplasty (UKA) with either titanium niobium nitride (TiNbN) alloy implants or with fixed-bearing oxidized zirconium alloy implants. Methods: The records of two consecutive cohorts for a total of 86 hypoallergenic implants were prospectively analyzed. The first cohort consisted of 49 consecutive implantations of the hypoallergenic UKA Journey Uni Oxinium (Ox Group), while the second consisted of 37 consecutive series of UKA Oxford (TiNbN Group). All patients were evaluated by two independent surgeons who were not involved in the index surgery. The clinical evaluation consisted of evaluating each patient’s Oxford Knee Score and Knee Society Score day before surgery (T0), and with two consecutive follow-ups at T1 (minimum follow-up 9 months) and T2 (minimum follow-up 24 months). Results: The two groups were homogeneous in all preoperative values, except Body Mass Index (BMI) and duration of final follow-up [both statistically higher (p < 0.05) in the TiNbN group]. Both groups showed a clinically significant improvement for all scores at final follow-up (p < 0.05). The only differences between the two groups involved a higher pre-operative Oxford Score in TiNbN group (p = 0.031), and different tibial and femoral angles at the final follow-up. Conclusions: Both TiNbN and Oxinium UKA procedures enabled patients from good to excellent clinical and radiographic outcomes after the final follow-up, regardless of the age, gender, BMI bearing type, and implant size. Level of evidence: Level II: Comparative study.File | Dimensione | Formato | |
---|---|---|---|
s00590-022-03295-y.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
693.7 kB
Formato
Adobe PDF
|
693.7 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.