Purpose Cruciate-retaining and posterior-stabilised implant designs are available for primary total knee arthroplasty. However, whether the implant design is associated with a difference in the level of activity still remains unclear. This clinical trial compared posterior-stabilised and cruciate-retaining implants in sport-related patient-reported outcome measures, range of motion, rate of return to sport, and weekly time dedicated to sport in active adults. It was also hypothesised that in young and active patients both implants lead to a similar rate of return to sport in terms of hours per week, type of sport, and joint mobility. Methods All patients were evaluated preoperatively and for a minimum of 36 months follow-up. The University of California Los Angeles activity scores, High-Activity Arthroplasty Score, and Visual Analogue Scale were administered preoperatively and at the last follow-up. The range of motion was investigated at admission and the last follow-up. Data concerning the hours per week dedicated to sports and the type of sport practiced were also collected at admission and at the last follow-up. The Kaplan-Meier Curve was performed to compare implant survivorship. Results Data from 227 procedures (cruciate-retaining: 109, posterior-stabilised: 118) were prospectively collected. At the last follow-up, no difference was reported in The University of California Los Angeles activity scores (p = 0.6), High-Activity Arthroplasty Score (p = 0.1), Visual Analogue Scale (p = 0.9), flexion (p = 0.7) and extension (p = 0.4). No difference was found in the rate of return (p = 0.1) and weekly hours dedicated to sport (p = 0.3). The Kaplan-Meier curve evidenced no statistically significant difference in implant survivorship (p = 0.6). Conclusions At approximately five years of follow-up, no difference was reported between cruciate-retaining and posterior-stabilised implants in active adults in sport-related patient-reported outcomes measures, range of motion, pain, weekly time dedicated to sport, rate of return to sport, and implant survivorship.

Similar rate of return to sports activity between posterior-stabilised and cruciate-retaining primary total knee arthroplasty in young and active patient / R. D'Ambrosi, L. Mangiavini, R. Loucas, M. Loucas, A. Brivio, I. Mariani, N. Ursino, F. Migliorini. - In: KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY. - ISSN 1433-7347. - (2022 Nov 02), pp. 1-11. [10.1007/s00167-022-07176-z]

Similar rate of return to sports activity between posterior-stabilised and cruciate-retaining primary total knee arthroplasty in young and active patient

R. D'Ambrosi
;
L. Mangiavini;A. Brivio;
2022

Abstract

Purpose Cruciate-retaining and posterior-stabilised implant designs are available for primary total knee arthroplasty. However, whether the implant design is associated with a difference in the level of activity still remains unclear. This clinical trial compared posterior-stabilised and cruciate-retaining implants in sport-related patient-reported outcome measures, range of motion, rate of return to sport, and weekly time dedicated to sport in active adults. It was also hypothesised that in young and active patients both implants lead to a similar rate of return to sport in terms of hours per week, type of sport, and joint mobility. Methods All patients were evaluated preoperatively and for a minimum of 36 months follow-up. The University of California Los Angeles activity scores, High-Activity Arthroplasty Score, and Visual Analogue Scale were administered preoperatively and at the last follow-up. The range of motion was investigated at admission and the last follow-up. Data concerning the hours per week dedicated to sports and the type of sport practiced were also collected at admission and at the last follow-up. The Kaplan-Meier Curve was performed to compare implant survivorship. Results Data from 227 procedures (cruciate-retaining: 109, posterior-stabilised: 118) were prospectively collected. At the last follow-up, no difference was reported in The University of California Los Angeles activity scores (p = 0.6), High-Activity Arthroplasty Score (p = 0.1), Visual Analogue Scale (p = 0.9), flexion (p = 0.7) and extension (p = 0.4). No difference was found in the rate of return (p = 0.1) and weekly hours dedicated to sport (p = 0.3). The Kaplan-Meier curve evidenced no statistically significant difference in implant survivorship (p = 0.6). Conclusions At approximately five years of follow-up, no difference was reported between cruciate-retaining and posterior-stabilised implants in active adults in sport-related patient-reported outcomes measures, range of motion, pain, weekly time dedicated to sport, rate of return to sport, and implant survivorship.
Activity; Arthroplasty; Cruciate-retaining; Knee; Posterior-stabilised; Sport
Settore MED/33 - Malattie Apparato Locomotore
2-nov-2022
Article (author)
File in questo prodotto:
File Dimensione Formato  
In elite athletes with meniscal injuries, always repair the lateral.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 567.22 kB
Formato Adobe PDF
567.22 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/945880
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact