Background and aim Rapid antigen detection (RAD) tests on nasopharyngeal specimens have been recently made available for SARS-CoV-2 infections, and early studies suggested their potential utilization as rapid screening and diagnostic testing. The present systematic review and meta-analysis was aimed to assess available evidence and to explore the reliability of antigenic tests in the management of the SARS-CoV-2 pandemic. Materials and Methods. We reported our meta-analysis according to the PRISMA statement. We searched Pubmed, Embase, and pre-print archive medRxiv.og for eligible studies published up to November 5th, 2020. Raw data included true/false positive and negative tests, and the total number of tests. Sensitivity and specificity data were calculated for every study, and then pooled in a random-effects model. Heterogeneity was assessed using the I2 measure. Reporting bias was assessed by means of funnel plots and regression analysis. Results. Based on 25 studies, we computed a pooled sensitivity of 72.8% (95%CI 62.4–81.3), a specificity of 99.4% (95%CI 99.0–99.7), with high heterogeneity and risk of reporting bias. More precisely, RAD tests exhibited higher sensitivity on samples with high viral load (i.e. <25 Cycle Threshold; 97.6%; 95%CI 94.1–99.0), compared to those with low viral load (≥25 Cycle Threshold; 43.6%; 95% 27.6-61.1). Discussion. As the majority of collected reports were either cohort or case-control studies, deprived of preventive power analysis and often oversampling positive tests, overall performances may have been overestimated. Therefore, the massive referral to antigenic tests in place of RT-qPCR is currently questionable, and also their deployment as mass screening test may lead to intolerable share of missing diagnoses. On the other hand, RAD tests may find a significant role in primary care and in front-line settings (e.g. Emergency Departments). (www. actabiomedica.it).

Antigen Detection Tests for SARS-CoV-2: a systematic review and meta-analysis on real world data / M. Riccò, S. Ranzieri, S. Peruzzi, M. Valente, F. Marchesi, N.L. Bragazzi, D. Donelli, F. Balzarini, P. Ferraro, V. Gianfredi, C. Signorelli. - In: ACTA BIOMEDICA. - ISSN 2531-6745. - 93:2(2022 May 11), pp. e2022036.1-e2022036.21. [10.23750/abm.v93i2.11031]

Antigen Detection Tests for SARS-CoV-2: a systematic review and meta-analysis on real world data

V. Gianfredi
Penultimo
Formal Analysis
;
2022

Abstract

Background and aim Rapid antigen detection (RAD) tests on nasopharyngeal specimens have been recently made available for SARS-CoV-2 infections, and early studies suggested their potential utilization as rapid screening and diagnostic testing. The present systematic review and meta-analysis was aimed to assess available evidence and to explore the reliability of antigenic tests in the management of the SARS-CoV-2 pandemic. Materials and Methods. We reported our meta-analysis according to the PRISMA statement. We searched Pubmed, Embase, and pre-print archive medRxiv.og for eligible studies published up to November 5th, 2020. Raw data included true/false positive and negative tests, and the total number of tests. Sensitivity and specificity data were calculated for every study, and then pooled in a random-effects model. Heterogeneity was assessed using the I2 measure. Reporting bias was assessed by means of funnel plots and regression analysis. Results. Based on 25 studies, we computed a pooled sensitivity of 72.8% (95%CI 62.4–81.3), a specificity of 99.4% (95%CI 99.0–99.7), with high heterogeneity and risk of reporting bias. More precisely, RAD tests exhibited higher sensitivity on samples with high viral load (i.e. <25 Cycle Threshold; 97.6%; 95%CI 94.1–99.0), compared to those with low viral load (≥25 Cycle Threshold; 43.6%; 95% 27.6-61.1). Discussion. As the majority of collected reports were either cohort or case-control studies, deprived of preventive power analysis and often oversampling positive tests, overall performances may have been overestimated. Therefore, the massive referral to antigenic tests in place of RT-qPCR is currently questionable, and also their deployment as mass screening test may lead to intolerable share of missing diagnoses. On the other hand, RAD tests may find a significant role in primary care and in front-line settings (e.g. Emergency Departments). (www. actabiomedica.it).
Humans; Pandemics; Reproducibility of Results; Sensitivity and Specificity; COVID-19; SARS-CoV-2;
Settore MED/42 - Igiene Generale e Applicata
11-mag-2022
https://www.mattioli1885journals.com/index.php/actabiomedica/article/view/11031
Article (author)
File in questo prodotto:
File Dimensione Formato  
abm-11031.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/944211
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact