Aim. In the critically ill patient the hemodynamic management is essential. Usually the hemodynamic status is estimated by the measurement of the intravascular pressure or volume and by computing the fluid balance, while the change in body weight estimates the total body water. The fluid balance is computed by subtracting the fluid output to the input. Although the input (fluids, drugs, infusion....) are well known, the output are difficult to correctly compute, because they depend on several factors such as the body-room temperature, amount of humidity and may change with time. Aim of this study was to prospectively evaluate the accuracy of the fluid balance compared to the body weight measured by a dedicated mattress (Hill-Rom®). Methods. Fifteen critically ill patients were enrolled (mean age of 63.2±19.7 years, body mass index of 24.9±3.5 kg/m2) and the measurements were computed every 8 hours. The data were analyzed by the Bland-Altman test. Results. Four-hundred and seventy-two measurements for a mean intensive care stay of 12.3.±7.3 days were computed. The Bland-Altamn showed a great inaccuracy, because the agreement (the difference between the 2 methods) was poor with a standard deviation of 1 840 L. Conclusion. Although the fluid balance was not accurate, the only body weight without any intravascular measurement is not helpful for a correct clinical hemodynamic management of the patient.

Il bilancio idrico nel malato di terapia intensiva / P. Bruzzone, D. Chiumello, P. Altavilla, G. Saia, F. Scopacasa, L. Gattinoni. - In: MINERVA ANESTESIOLOGICA. - ISSN 0375-9393. - 70:5(2004), pp. 431-436.

Il bilancio idrico nel malato di terapia intensiva

D. Chiumello;P. Altavilla;G. Saia;L. Gattinoni
2004

Abstract

Aim. In the critically ill patient the hemodynamic management is essential. Usually the hemodynamic status is estimated by the measurement of the intravascular pressure or volume and by computing the fluid balance, while the change in body weight estimates the total body water. The fluid balance is computed by subtracting the fluid output to the input. Although the input (fluids, drugs, infusion....) are well known, the output are difficult to correctly compute, because they depend on several factors such as the body-room temperature, amount of humidity and may change with time. Aim of this study was to prospectively evaluate the accuracy of the fluid balance compared to the body weight measured by a dedicated mattress (Hill-Rom®). Methods. Fifteen critically ill patients were enrolled (mean age of 63.2±19.7 years, body mass index of 24.9±3.5 kg/m2) and the measurements were computed every 8 hours. The data were analyzed by the Bland-Altman test. Results. Four-hundred and seventy-two measurements for a mean intensive care stay of 12.3.±7.3 days were computed. The Bland-Altamn showed a great inaccuracy, because the agreement (the difference between the 2 methods) was poor with a standard deviation of 1 840 L. Conclusion. Although the fluid balance was not accurate, the only body weight without any intravascular measurement is not helpful for a correct clinical hemodynamic management of the patient.
Body weight; Critically ill patients; Hemodynamics; Idric balance
Settore MED/41 - Anestesiologia
2004
Article (author)
File in questo prodotto:
File Dimensione Formato  
R02Y2004N05A0431.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 188.17 kB
Formato Adobe PDF
188.17 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/940569
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact