Objective The English Diabetic Eye Screening (DES) programme recommends patients with M1 diabetic maculopathy to be referred to hospital eye services. DES uses flash fundus photography as the reference standard for maculopathy grading. We compared multicolour versus non-stereoscopic fundus photography at identifying M1 maculopathy, with spectral domain optical coherence tomography (SD-OCT) identifying macular thickening. Methods and analysis This cross-sectional study included 345 patients with R1M1 referred from DES and reviewed in secondary care with fundus photographs, multicolour and SD-OCT. Maculopathy was graded based on DES exudate criteria on both multicolour and fundus photography in a blind fashion by two independent graders. Macular thickness was ascertained on SD-OCT. Results Intergrader agreement on grading maculopathy using fundus photography (Cohen's κ=0.91) and multicolour (Cohen's κ=0.82) was 'almost perfect'. Agreement between fundus photography and multicolour on grading maculopathy (Cohen's κ=0.76) was 'substantial'. Compared with fundus photography, multicolour had sensitivity of 87% (95% CI 81% to 93%) and specificity of 90% (95% CI 87% to 94%) in detecting M1 maculopathy. SD-OCT identified 84 eyes with macular thickening, 47 of which were graded as M0 by fundus photography. 5 eyes with exudates and severe macular oedema requiring urgent intervention were also missed on fundus photography but not on multicolour. Multicolour, when complemented by SD-OCT, did not miss any clinically significant macular oedema. Conclusion Multicolour integrates synergistically in a single platform with SD-OCT providing effective monitoring of M1 diabetic maculopathy. The need for fundus photography is eliminated by multicolour/SD-OCT in dedicated R1M1 virtual clinics not requiring parallel diabetic retinopathy grading.

Diabetic maculopathy: Multicolour and SD-OCT versus fundus photography / O. Kousha, M. Delle Fave, M. Cozzi, E. Carini, S. Pagliarini. - In: BMJ OPEN OPHTHALMOLOGY. - ISSN 2397-3269. - 6:1(2021), pp. e000514.1-e000514.6. [10.1136/bmjophth-2020-000514]

Diabetic maculopathy: Multicolour and SD-OCT versus fundus photography

M. Cozzi;E. Carini
Penultimo
;
2021

Abstract

Objective The English Diabetic Eye Screening (DES) programme recommends patients with M1 diabetic maculopathy to be referred to hospital eye services. DES uses flash fundus photography as the reference standard for maculopathy grading. We compared multicolour versus non-stereoscopic fundus photography at identifying M1 maculopathy, with spectral domain optical coherence tomography (SD-OCT) identifying macular thickening. Methods and analysis This cross-sectional study included 345 patients with R1M1 referred from DES and reviewed in secondary care with fundus photographs, multicolour and SD-OCT. Maculopathy was graded based on DES exudate criteria on both multicolour and fundus photography in a blind fashion by two independent graders. Macular thickness was ascertained on SD-OCT. Results Intergrader agreement on grading maculopathy using fundus photography (Cohen's κ=0.91) and multicolour (Cohen's κ=0.82) was 'almost perfect'. Agreement between fundus photography and multicolour on grading maculopathy (Cohen's κ=0.76) was 'substantial'. Compared with fundus photography, multicolour had sensitivity of 87% (95% CI 81% to 93%) and specificity of 90% (95% CI 87% to 94%) in detecting M1 maculopathy. SD-OCT identified 84 eyes with macular thickening, 47 of which were graded as M0 by fundus photography. 5 eyes with exudates and severe macular oedema requiring urgent intervention were also missed on fundus photography but not on multicolour. Multicolour, when complemented by SD-OCT, did not miss any clinically significant macular oedema. Conclusion Multicolour integrates synergistically in a single platform with SD-OCT providing effective monitoring of M1 diabetic maculopathy. The need for fundus photography is eliminated by multicolour/SD-OCT in dedicated R1M1 virtual clinics not requiring parallel diabetic retinopathy grading.
diagnostic tests/investigation; imaging; macula; retina; treatment medical
Settore MED/50 - Scienze Tecniche Mediche Applicate
Settore MED/30 - Malattie Apparato Visivo
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
e000514.full.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 891.4 kB
Formato Adobe PDF
891.4 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/938278
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact