There is still uncertainity about the use of computed tomography-scan for left atrial appendage occlusion (LAAO) device sizing. The main reason for this disappointing position is likely to relate to the scarcity of robust data, since there is still difference among institutions with regards how to perform measurement of the devices. Dallan et al. report their own experience on the use of a novel computed tomography angiography-based (CTA) for sizing the Watchman Flex device for LAAO. The authors through the TruPlan software package that a preprocedural CTA sizing protocol can be applied successfully with intracardiac echocardiography guidance and provide excellent procedural outcomes. The applied CTA protocol is safe and can provide high success rates with the WatchmanTM FLX device reducing the number of deployment attempts and reducing the risk of complications.

Seize the day, …s(e)ize the device: The emerging imaging modality to improve left atrial appendage device sizing / C. Tondo. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1540-8167. - (2022). [Epub ahead of print] [10.1111/jce.15547]

Seize the day, …s(e)ize the device: The emerging imaging modality to improve left atrial appendage device sizing

C. Tondo
2022

Abstract

There is still uncertainity about the use of computed tomography-scan for left atrial appendage occlusion (LAAO) device sizing. The main reason for this disappointing position is likely to relate to the scarcity of robust data, since there is still difference among institutions with regards how to perform measurement of the devices. Dallan et al. report their own experience on the use of a novel computed tomography angiography-based (CTA) for sizing the Watchman Flex device for LAAO. The authors through the TruPlan software package that a preprocedural CTA sizing protocol can be applied successfully with intracardiac echocardiography guidance and provide excellent procedural outcomes. The applied CTA protocol is safe and can provide high success rates with the WatchmanTM FLX device reducing the number of deployment attempts and reducing the risk of complications.
cardiac anatomy; clinical
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
2022
18-mag-2022
Article (author)
File in questo prodotto:
File Dimensione Formato  
Seize.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 151.27 kB
Formato Adobe PDF
151.27 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/934939
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact