In this study, simultaneous monitoring of indoor and outdoor Volatile Organic Compounds (VOCs) was carried out in a school, by both Radiello® cartridges and real‐time monitors (Corvus, IonScience Ltd., Fowlmere UK). Moreover, an outdoor air quality assessment was performed with data from an air quality monitoring station (ARPA Puglia) located close to the school. In particular, VOCs, Benzene, Toluene, Ethylbenzene, and Xilenes concentrations, obtained by using Radiello® diffusive samplers, were monitored in two classrooms, two bathrooms, and outside of the school building for three weeks during winter 2019. Simultaneously, the Total VOC (TVOC) concentrations were measured by means of real‐time monitors inside and outside the classroom in order to individuate the activation of sources during the sampling campaign days. The results evidence that indoor TVOC concentrations were bigger than those outdoors; this suggests the presence of indoor pollutant sources, both in the classrooms and the bathrooms. The results of our study can help the school management by the following recommendations: increasing ventilation in classrooms during school activities and after cleaning; involving students in discussions regarding the use of acrylic paints, permanent markers, perfumes and deodorants, and the limitation of smoking activities both in bathrooms and outdoor spaces.

Air quality assessment of a school in an industrialized area of southern Italy / P. Ielpo, C. Mangia, G. de Gennaro, A.D. Gilio, J. Palmisani, A. Dinoi, A. Bergomi, V. Comite, P. Fermo. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 11:19(2021), pp. 8870.1-8870.11. [10.3390/app11198870]

Air quality assessment of a school in an industrialized area of southern Italy

A. Bergomi;V. Comite
Penultimo
;
P. Fermo
Ultimo
2021

Abstract

In this study, simultaneous monitoring of indoor and outdoor Volatile Organic Compounds (VOCs) was carried out in a school, by both Radiello® cartridges and real‐time monitors (Corvus, IonScience Ltd., Fowlmere UK). Moreover, an outdoor air quality assessment was performed with data from an air quality monitoring station (ARPA Puglia) located close to the school. In particular, VOCs, Benzene, Toluene, Ethylbenzene, and Xilenes concentrations, obtained by using Radiello® diffusive samplers, were monitored in two classrooms, two bathrooms, and outside of the school building for three weeks during winter 2019. Simultaneously, the Total VOC (TVOC) concentrations were measured by means of real‐time monitors inside and outside the classroom in order to individuate the activation of sources during the sampling campaign days. The results evidence that indoor TVOC concentrations were bigger than those outdoors; this suggests the presence of indoor pollutant sources, both in the classrooms and the bathrooms. The results of our study can help the school management by the following recommendations: increasing ventilation in classrooms during school activities and after cleaning; involving students in discussions regarding the use of acrylic paints, permanent markers, perfumes and deodorants, and the limitation of smoking activities both in bathrooms and outdoor spaces.
Air quality monitoring station; Indoor air quality; Outdoor air quality; Volatile organic compound (VOC)
Settore CHIM/01 - Chimica Analitica
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
applsci-11-08870-v2.pdf

accesso aperto

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 1.88 MB
Formato Adobe PDF
1.88 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/921910
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 8
social impact