Continuous recording of Visual Evoked Potentials (VEPs) and functional Magnetic Resonance Imaging (fMRI) exploits the VEPs high temporal resolution and the fMRI high spatial resolution. In this work, we present a new method of continuous VEPs/fMRI recording to study visual function in seven normal subjects. Our real-time artifact filtering is characterized by a procedure based on an analytical study of echo-planar imaging (EPI) sequence parameters related electro-encephalogram (EEG)-artifact shapes. The magnetic field artifacts were minimized by using a dedicated amagnetic device and by a subtraction algorithm that takes into account the EPI sequence parameters. No significant decrease in signal-to-noise ratio was observed in case of EEG recording simultaneously with MR acquisition; similarly, transient and steady-state VEPs parameters were comparable during fMRI acquisition and in the off-phase of fMRI recording. We also applied this method to one patient with optic neuritis, and, compared with controls, found different results. We suggest that our technique can be reliably used to investigate the function of human visual cortex and properly correlate the electrophysiological and functional neuroimaging related changes. © 2009 Elsevier B.V. All rights reserved.

Real-time artifact filtering in continuous VEPs/fMRI recording / M.N. Anwar, L. Bonzano, D.R. Sebastiano, L. Roccatagliata, G. Gualniera, P. Vitali, C. Ogliastro, L. Spadavecchia, G. Rodriguez, V. Sanguineti, P. Morasso, F. Bandini. - In: JOURNAL OF NEUROSCIENCE METHODS. - ISSN 0165-0270. - 184:2(2009 Nov 15), pp. 213-223. [10.1016/j.jneumeth.2009.08.003]

Real-time artifact filtering in continuous VEPs/fMRI recording

L. Roccatagliata;P. Vitali;
2009

Abstract

Continuous recording of Visual Evoked Potentials (VEPs) and functional Magnetic Resonance Imaging (fMRI) exploits the VEPs high temporal resolution and the fMRI high spatial resolution. In this work, we present a new method of continuous VEPs/fMRI recording to study visual function in seven normal subjects. Our real-time artifact filtering is characterized by a procedure based on an analytical study of echo-planar imaging (EPI) sequence parameters related electro-encephalogram (EEG)-artifact shapes. The magnetic field artifacts were minimized by using a dedicated amagnetic device and by a subtraction algorithm that takes into account the EPI sequence parameters. No significant decrease in signal-to-noise ratio was observed in case of EEG recording simultaneously with MR acquisition; similarly, transient and steady-state VEPs parameters were comparable during fMRI acquisition and in the off-phase of fMRI recording. We also applied this method to one patient with optic neuritis, and, compared with controls, found different results. We suggest that our technique can be reliably used to investigate the function of human visual cortex and properly correlate the electrophysiological and functional neuroimaging related changes. © 2009 Elsevier B.V. All rights reserved.
Continuous recording; Functional Magnetic Resonance Imaging (fMRI); Optic neuritis; Real-time filtering; Steady-state and transient Visual Evoked Potentials (VEPs)
Settore MED/37 - Neuroradiologia
15-nov-2009
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0165027009004361-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.98 MB
Formato Adobe PDF
1.98 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/912701
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact