IMPORTANCE After neoadjuvant chemotherapy (NAC), pathologic complete response (pCR) is an optimal outcome and a surrogate end point for improved disease-free and overall survival. To date, surgical resection remains the only reliable method for diagnosing pCR. OBJECTIVE To evaluate the accuracy of magnetic resonance imaging (MRI)-guided biopsy for diagnosing a pCR after NAC compared with reference-standard surgical resection. DESIGN, SETTING, AND PARTICIPANTS Single-arm, phase 1, nonrandomized controlled trial in a single tertiary care cancer center from September 26, 2017, to July 29, 2019. The median follow-up was 1.26 years (interquartile range, 0.85-1.59 years). Data analysis was performed in November 2019. Eligible patients had (1) stage IA to IIIC biopsy-proven operable invasive breast cancer; (2) standard-of-care NAC; (3) MRI before and after NAC, with imaging complete response defined as no residual enhancement on post-NAC MRI; and (4) definitive surgery. Patients were excluded if they were younger than 18 years, had a medical reason precluding study participation, or had a prior history of breast cancer. INTERVENTIONS Post-NAC MRI-guided biopsy without the use of intravenous contrast of the tumor bed before definitive surgery. MAIN OUTCOMES AND MEASURES The primary end point was the negative predictive value of MRI-guided biopsy, with true-negative defined as negative results of the biopsy (ie, no residual cancer) corresponding to a surgical pCR. Accuracy, sensitivity, positive predictive value, and specificity were also calculated. Two clinical definitions of pCR were independently evaluated: definition 1 was no residual invasive cancer; definition 2, no residual invasive or in situ cancer. RESULTS Twenty of 23 patients (87%) had evaluable data (median [interquartile range] age, 51.5 [39.0-57.5] years; 20 women [100%]; 13 White patients [65%]). Of the 20 patients, pre-NAC median tumor size on MRI was 3.0 cm (interquartile range, 2.0-5.0 cm). Nineteen of 20 patients (95%) had invasive ductal carcinoma; 15 of 20 (75%) had stage II cancer; 11 of 20 (55%) had ERBB2 (formerly HER2 or HER2/neu)-positive cancer; and 6 of 20 (30%) had triple-negative cancer. Surgical pathology demonstrated a pCR in 13 of 20 (65%) patients and no pCR in 7 of 20 patients (35%) when pCR definition 1 was used. Results of MRI-guided biopsy had a negative predictive value of 92.8% (95% CI, 66.2%-99.8%), with accuracy of 95% (95% CI, 75.1%-99.9%), sensitivity of 85.8% (95% CI, 42.0%-99.6%), positive predictive value of 100%, and specificity of 100% for pCR definition 1. Only 1 patient had a false-negative MRI-guided biopsy result (surgical pathology showed <0.02 cm of residual invasive cancer). CONCLUSIONS AND RELEVANCE This study's results suggest that the accuracy of MRI-guided biopsy to diagnose a post-NAC pCR approaches that of reference-standard surgical resection. MRI-guided biopsy may be a viable alternative to surgical resection for this population after NAC, which supports the need for further investigation.

Accuracy of Magnetic Resonance Imaging-Guided Biopsy to Verify Breast Cancer Pathologic Complete Response After Neoadjuvant Chemotherapy: A Nonrandomized Controlled Trial / E. Sutton, L. Braunstein, M. El-Tamer, E. Brogi, M. Hughes, Y. Bryce, J. Gluskin, S. Powell, A. Woosley, A. Tadros, V. Sevilimedu, D. Martinez, L. Toni, O. Smelianskaia, C. Nyman, P. Razavi, L. Norton, M. Fung, J. Sedorovich, V. Sacchini, E. Morris. - In: JAMA NETWORK OPEN. - ISSN 2574-3805. - 4:1(2021 Jan 15), pp. e2034045.1-e2034045.10. [10.1001/jamanetworkopen.2020.34045]

Accuracy of Magnetic Resonance Imaging-Guided Biopsy to Verify Breast Cancer Pathologic Complete Response After Neoadjuvant Chemotherapy: A Nonrandomized Controlled Trial

V. Sacchini
Penultimo
;
2021

Abstract

IMPORTANCE After neoadjuvant chemotherapy (NAC), pathologic complete response (pCR) is an optimal outcome and a surrogate end point for improved disease-free and overall survival. To date, surgical resection remains the only reliable method for diagnosing pCR. OBJECTIVE To evaluate the accuracy of magnetic resonance imaging (MRI)-guided biopsy for diagnosing a pCR after NAC compared with reference-standard surgical resection. DESIGN, SETTING, AND PARTICIPANTS Single-arm, phase 1, nonrandomized controlled trial in a single tertiary care cancer center from September 26, 2017, to July 29, 2019. The median follow-up was 1.26 years (interquartile range, 0.85-1.59 years). Data analysis was performed in November 2019. Eligible patients had (1) stage IA to IIIC biopsy-proven operable invasive breast cancer; (2) standard-of-care NAC; (3) MRI before and after NAC, with imaging complete response defined as no residual enhancement on post-NAC MRI; and (4) definitive surgery. Patients were excluded if they were younger than 18 years, had a medical reason precluding study participation, or had a prior history of breast cancer. INTERVENTIONS Post-NAC MRI-guided biopsy without the use of intravenous contrast of the tumor bed before definitive surgery. MAIN OUTCOMES AND MEASURES The primary end point was the negative predictive value of MRI-guided biopsy, with true-negative defined as negative results of the biopsy (ie, no residual cancer) corresponding to a surgical pCR. Accuracy, sensitivity, positive predictive value, and specificity were also calculated. Two clinical definitions of pCR were independently evaluated: definition 1 was no residual invasive cancer; definition 2, no residual invasive or in situ cancer. RESULTS Twenty of 23 patients (87%) had evaluable data (median [interquartile range] age, 51.5 [39.0-57.5] years; 20 women [100%]; 13 White patients [65%]). Of the 20 patients, pre-NAC median tumor size on MRI was 3.0 cm (interquartile range, 2.0-5.0 cm). Nineteen of 20 patients (95%) had invasive ductal carcinoma; 15 of 20 (75%) had stage II cancer; 11 of 20 (55%) had ERBB2 (formerly HER2 or HER2/neu)-positive cancer; and 6 of 20 (30%) had triple-negative cancer. Surgical pathology demonstrated a pCR in 13 of 20 (65%) patients and no pCR in 7 of 20 patients (35%) when pCR definition 1 was used. Results of MRI-guided biopsy had a negative predictive value of 92.8% (95% CI, 66.2%-99.8%), with accuracy of 95% (95% CI, 75.1%-99.9%), sensitivity of 85.8% (95% CI, 42.0%-99.6%), positive predictive value of 100%, and specificity of 100% for pCR definition 1. Only 1 patient had a false-negative MRI-guided biopsy result (surgical pathology showed <0.02 cm of residual invasive cancer). CONCLUSIONS AND RELEVANCE This study's results suggest that the accuracy of MRI-guided biopsy to diagnose a post-NAC pCR approaches that of reference-standard surgical resection. MRI-guided biopsy may be a viable alternative to surgical resection for this population after NAC, which supports the need for further investigation.
Settore MED/18 - Chirurgia Generale
15-gen-2021
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
sutton_2021_oi_201035_1610549602.73567.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 994.48 kB
Formato Adobe PDF
994.48 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/910644
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 22
social impact