Coronary computed tomography angiography (CCTA) is now an established tool in the diagnostic work-up of patients suspected to have coronary artery disease. Yet, its usefulness beyond this phase has not been fully explored. The current review focuses on the implementation of CCTA as a tool to plan and guide coronary interventions in the catheterization laboratory. Specifically, we explore the potential of CCTA to improve patient selection for percutaneous revascularization, provide the rationale for better resource use, and present a novel approach to incorporate 3-dimensional CT guidance for percutaneous coronary interventions.

Implementing Coronary Computed Tomography Angiography in the Catheterization Laboratory / C. Collet, J. Sonck, J. Leipsic, G. Monizzi, D. Buytaert, P. Kitslaar, D. Andreini, B. De Bruyne. - In: JACC. CARDIOVASCULAR IMAGING. - ISSN 1936-878X. - 14:9(2021 Sep), pp. 1846-1855. [10.1016/j.jcmg.2020.07.048]

Implementing Coronary Computed Tomography Angiography in the Catheterization Laboratory

G. Monizzi;D. Andreini;
2021

Abstract

Coronary computed tomography angiography (CCTA) is now an established tool in the diagnostic work-up of patients suspected to have coronary artery disease. Yet, its usefulness beyond this phase has not been fully explored. The current review focuses on the implementation of CCTA as a tool to plan and guide coronary interventions in the catheterization laboratory. Specifically, we explore the potential of CCTA to improve patient selection for percutaneous revascularization, provide the rationale for better resource use, and present a novel approach to incorporate 3-dimensional CT guidance for percutaneous coronary interventions.
cath lab; conventional angiography; coronary artery disease; CT-guided PCI; Catheterization; Coronary Angiography; Humans; Laboratories; Predictive Value of Tests; Tomography, X-Ray Computed; Computed Tomography Angiography; Coronary Artery Disease
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
set-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1936878X20309116-main.pdf

solo utenti autorizzati

Tipologia: Publisher's version/PDF
Dimensione 3.33 MB
Formato Adobe PDF
3.33 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/909040
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 25
social impact