Objective. This paper describes a method to extract upper limb intention tremor from gyroscope data, through the Hilbert-Huang transform (HHT), a technique suitable for the study of nonlinear and non-stationary processes. The aims of the study were to: (i) evaluate the method's ability to discriminate between healthy controls and MS subjects; (ii) validate the proposed procedure against clinical tremor scores assigned using Fahn's tremor rating scale (FTRS); and (iii) compare the performance of the HHT-based method with that of linear band-pass filters. Approach. HHT was applied on gyroscope data collected on 20 MS subjects and 13 healthy controls (CO) during finger-to-nose tests (FNTs) instrumented with an inertial sensor placed on the hand. The results were compared to those obtained after traditional linear filtering. The tremor amplitude was quantified with instrumental indexes (TIs) and clinical FTRS ratings. Main results. The TIs computed after HHT-based filtering discriminated between CO and MS subjects with clinically-detected intention tremor (MS_T). In particular, TIs were significantly higher in the final part of the movement (TI2) with respect to the first part (TI1), and, for all components (X, Y, Z), MS_T showed a TI2 significantly higher than in CO subjects. Moreover, the HHT detected subtle alterations not visible from clinical ratings, as TI2 (Z-component) was significantly increased in MS subjects without clinically-detected tremor (MS_NT). The method's validity was demonstrated by significant correlations between clinical FTRS scores and TI2 related to X (rs = 0.587, p = 0.006) and Y (rs = 0.682, p < 0.001) components. Contrarily, fewer differences among the groups and no correlation between instrumental and clinical indexes emerged after traditional filtering. Significance. The present results supported the use of the HHT-based procedure for a fully-automated quantitative and objective measure of intention tremor in MS, which can overcome the limitations of clinical scales and provide supplementary information about this sign.

Hilbert-Huang transform based instrumental assessment of intention tremor in multiple sclerosis / I. Carpinella, D. Cattaneo, M. Ferrarin. - In: JOURNAL OF NEURAL ENGINEERING. - ISSN 1741-2560. - 12:4(2015 Aug), pp. 046011.1-046011.12. [10.1088/1741-2560/12/4/046011]

Hilbert-Huang transform based instrumental assessment of intention tremor in multiple sclerosis

D. Cattaneo
Secondo
;
2015

Abstract

Objective. This paper describes a method to extract upper limb intention tremor from gyroscope data, through the Hilbert-Huang transform (HHT), a technique suitable for the study of nonlinear and non-stationary processes. The aims of the study were to: (i) evaluate the method's ability to discriminate between healthy controls and MS subjects; (ii) validate the proposed procedure against clinical tremor scores assigned using Fahn's tremor rating scale (FTRS); and (iii) compare the performance of the HHT-based method with that of linear band-pass filters. Approach. HHT was applied on gyroscope data collected on 20 MS subjects and 13 healthy controls (CO) during finger-to-nose tests (FNTs) instrumented with an inertial sensor placed on the hand. The results were compared to those obtained after traditional linear filtering. The tremor amplitude was quantified with instrumental indexes (TIs) and clinical FTRS ratings. Main results. The TIs computed after HHT-based filtering discriminated between CO and MS subjects with clinically-detected intention tremor (MS_T). In particular, TIs were significantly higher in the final part of the movement (TI2) with respect to the first part (TI1), and, for all components (X, Y, Z), MS_T showed a TI2 significantly higher than in CO subjects. Moreover, the HHT detected subtle alterations not visible from clinical ratings, as TI2 (Z-component) was significantly increased in MS subjects without clinically-detected tremor (MS_NT). The method's validity was demonstrated by significant correlations between clinical FTRS scores and TI2 related to X (rs = 0.587, p = 0.006) and Y (rs = 0.682, p < 0.001) components. Contrarily, fewer differences among the groups and no correlation between instrumental and clinical indexes emerged after traditional filtering. Significance. The present results supported the use of the HHT-based procedure for a fully-automated quantitative and objective measure of intention tremor in MS, which can overcome the limitations of clinical scales and provide supplementary information about this sign.
English
Settore MED/48 -Scienze Infermie.e Tecniche Neuro-Psichiatriche e Riabilitattive
Articolo
Esperti anonimi
Pubblicazione scientifica
ago-2015
Institute of Physics Publishing (IOP)
12
4
046011
1
12
12
Pubblicato
Periodico con rilevanza internazionale
MIUR-MANUAL
Aderisco
info:eu-repo/semantics/article
Hilbert-Huang transform based instrumental assessment of intention tremor in multiple sclerosis / I. Carpinella, D. Cattaneo, M. Ferrarin. - In: JOURNAL OF NEURAL ENGINEERING. - ISSN 1741-2560. - 12:4(2015 Aug), pp. 046011.1-046011.12. [10.1088/1741-2560/12/4/046011]
restricted
Prodotti della ricerca::01 - Articolo su periodico
3
262
Article (author)
no
I. Carpinella, D. Cattaneo, M. Ferrarin
File in questo prodotto:
File Dimensione Formato  
Carpinella - Hilbert–Huang transform based instrumental assmement of intention tremor in multiple sclerosis.pdf

solo utenti autorizzati

Tipologia: Publisher's version/PDF
Dimensione 871.18 kB
Formato Adobe PDF
871.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/907342
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact