Background Haemoptysis is usually caused by pulmonary and infectious diseases. In few cases, it has a cardiac cause, such as pulmonary embolism or mitral valve stenosis. Haemoptysis may be an uncommon symptom of prosthetic valve dysfunction, being related to elevated right heart pressures. Case summary A 22-year-old woman from sub-Saharan Africa known for a triple valve replacement was hospitalized for dyspnoea and haemoptysis. A careful clinical evaluation excluded the most common causes of haemoptysis. Transthoracic echocardiogram showed normal biventricular function, normally functioning mechanical prosthetic aortic and mitral valves, and the biological tricuspid prosthesis showed an increased transvalvular gradient. Contrast chest computed tomography scan excluded pulmonary embolism and mechanical valve obstruction, but revealed marked systemic venous hypertension. Right heart catheterization confirmed increased right heart pressures and severe bioprosthetic tricuspid valve stenosis. The patient underwent a successful percutaneous tricuspid valve-in-valve replacement, with complete resolution of symptoms. Discussion The increase in venous pressures due to bioprosthetic tricuspid stenosis caused veno-venous shunts: blood from the lower body was drained into the superior vena cava via the azygos vein. Increased pressure in the latter affected pressure in bronchial veins and arteries, leading to haemoptysis. Cardiac surgical reinterventions are associated with worse outcomes and higher mortality rates. Management of a degenerated prosthetic tricuspid valve is challenging and requires a multidisciplinary assessment. Transcatheter tricuspid valve replacement is becoming a feasible option in patients with prosthetic dysfunction. Based on evidence to date, tricuspid valve-in-valve replacement appears to be a safe, feasible, and effective alternative in selected young patients.

Bloody tricuspid stenosis: Case report of an uncommon cause of haemoptysis / F. Trombara, M. Bergonti, O. Toscano, A.D. Cia, E.M. Assanelli, G. Polvani, A.L. Bartorelli. - In: EUROPEAN HEART JOURNAL. CASE REPORTS. - ISSN 2514-2119. - 5:2(2021), pp. 5028093.1-5028093.5. [10.1093/ehjcr/ytaa537]

Bloody tricuspid stenosis: Case report of an uncommon cause of haemoptysis

F. Trombara
Primo
;
M. Bergonti
Secondo
;
O. Toscano;G. Polvani;
2021

Abstract

Background Haemoptysis is usually caused by pulmonary and infectious diseases. In few cases, it has a cardiac cause, such as pulmonary embolism or mitral valve stenosis. Haemoptysis may be an uncommon symptom of prosthetic valve dysfunction, being related to elevated right heart pressures. Case summary A 22-year-old woman from sub-Saharan Africa known for a triple valve replacement was hospitalized for dyspnoea and haemoptysis. A careful clinical evaluation excluded the most common causes of haemoptysis. Transthoracic echocardiogram showed normal biventricular function, normally functioning mechanical prosthetic aortic and mitral valves, and the biological tricuspid prosthesis showed an increased transvalvular gradient. Contrast chest computed tomography scan excluded pulmonary embolism and mechanical valve obstruction, but revealed marked systemic venous hypertension. Right heart catheterization confirmed increased right heart pressures and severe bioprosthetic tricuspid valve stenosis. The patient underwent a successful percutaneous tricuspid valve-in-valve replacement, with complete resolution of symptoms. Discussion The increase in venous pressures due to bioprosthetic tricuspid stenosis caused veno-venous shunts: blood from the lower body was drained into the superior vena cava via the azygos vein. Increased pressure in the latter affected pressure in bronchial veins and arteries, leading to haemoptysis. Cardiac surgical reinterventions are associated with worse outcomes and higher mortality rates. Management of a degenerated prosthetic tricuspid valve is challenging and requires a multidisciplinary assessment. Transcatheter tricuspid valve replacement is becoming a feasible option in patients with prosthetic dysfunction. Based on evidence to date, tricuspid valve-in-valve replacement appears to be a safe, feasible, and effective alternative in selected young patients.
Case report; Haemoptysis; Prosthetic valve; Transcatheter valve replacement; Tricuspid valve stenosis; Venous hypertension
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
2.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.86 MB
Formato Adobe PDF
1.86 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/907249
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact