Objective: To compare different stereotactic body techniques-intensity-modulated radiotherapy with photons and protons, applied to radiotherapy of prostatic cancer-with simultaneous integrated boost (SIB) on the dominant intraprostatic lesion (DIL). Methods: Ten patients were selected for this planning study. Dosimetric results were compared between volumetric modulated arc therapy, intensity-modulated radiation therapy (IMRT), and intensity-modulated proton therapy both with two (IMPT 2F) and five fields (IMPT 5F) planning while applying the prescription schemes of 7.25 Gy/fraction to the prostate gland and 7.5 Gy/fraction to the DIL in 5 fractions. Results: Comparison of the coverages of the planning target volumes showed that small differences exist. The IMPT-2F-5F techniques allowed higher doses in the targets; conformal indexes resulted similar; homogeneity was better in the photon techniques (2%-5%). Regarding the organs at risk, all the techniques were able to maintain the dose well below the prescribed constraints: in the rectum, the IMPT-2F-5F and IMRT were more efficient in lowering the intermediate doses; in the bladder, the median dose was significantly better in the case of IMPT (2F-5F). In the urethra, the best sparing was achieved only by IMPT-5F. Conclusions: Stereotactic radiotherapy with SIB for localized prostate cancer is feasible with all the investigated techniques. Concerning IMPT, the two-beam technique does not seem to have a greater advantage compared to the standard techniques; the 5-beam technique seems more promising also accounting for the range uncertainty.
Ultrahypofractionated radiotherapy for localized prostate cancer with simultaneous boost to the dominant intraprostatic lesion : a plan comparison / R. Cambria, D. Ciardo, A. Bazani, F. Pansini, E. Rondi, D. Maestri, D. Zerini, G. Marvaso, P. Romanelli, G. Timon, C. Fodor, G. Petralia, S. Alessi, P. Pricolo, B. Vischioni, P. Fossati, S. Molinelli, S. Russo, M. Ciocca, O. De Cobelli, G. Renne, R. Orecchia, F. Cattani, B.A. Jereczek-Fossa. - In: TUMORI. - ISSN 0300-8916. - 108:3(2022 Jun), pp. 263-269. [10.1177/03008916211011667]
Ultrahypofractionated radiotherapy for localized prostate cancer with simultaneous boost to the dominant intraprostatic lesion : a plan comparison
A. Bazani;D. Zerini;G. Marvaso;G. Petralia;P. Pricolo;B. Vischioni;P. Fossati;O. De Cobelli;R. Orecchia;B.A. Jereczek-FossaUltimo
2022
Abstract
Objective: To compare different stereotactic body techniques-intensity-modulated radiotherapy with photons and protons, applied to radiotherapy of prostatic cancer-with simultaneous integrated boost (SIB) on the dominant intraprostatic lesion (DIL). Methods: Ten patients were selected for this planning study. Dosimetric results were compared between volumetric modulated arc therapy, intensity-modulated radiation therapy (IMRT), and intensity-modulated proton therapy both with two (IMPT 2F) and five fields (IMPT 5F) planning while applying the prescription schemes of 7.25 Gy/fraction to the prostate gland and 7.5 Gy/fraction to the DIL in 5 fractions. Results: Comparison of the coverages of the planning target volumes showed that small differences exist. The IMPT-2F-5F techniques allowed higher doses in the targets; conformal indexes resulted similar; homogeneity was better in the photon techniques (2%-5%). Regarding the organs at risk, all the techniques were able to maintain the dose well below the prescribed constraints: in the rectum, the IMPT-2F-5F and IMRT were more efficient in lowering the intermediate doses; in the bladder, the median dose was significantly better in the case of IMPT (2F-5F). In the urethra, the best sparing was achieved only by IMPT-5F. Conclusions: Stereotactic radiotherapy with SIB for localized prostate cancer is feasible with all the investigated techniques. Concerning IMPT, the two-beam technique does not seem to have a greater advantage compared to the standard techniques; the 5-beam technique seems more promising also accounting for the range uncertainty.File | Dimensione | Formato | |
---|---|---|---|
03008916211011667.pdf
solo utenti autorizzati
Tipologia:
Publisher's version/PDF
Dimensione
190.9 kB
Formato
Adobe PDF
|
190.9 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.