Catheter ablation for atrial fibrillation (AF) is one of the most commonly performed electrophysiology procedures. Despite significant advances in our understanding of AF mechanisms in the last years, ablation outcomes remain suboptimal for many patients, particularly those with persistent or long-standing AF. A possible reason is that ablation techniques mainly focus on anatomic, rather than patient-specific functional targets for ablation. The identification of such ablation targets remains challenging. The purpose of this study is to investigate a novel approach based on directed networks, which allow the automatic detection of important arrhythmia mechanisms, that can be convenient for guiding the ablation strategy. The networks are generated by processing unipolar electrograms (EGMs) collected by the catheters positioned at the different regions of the atria. Network vertices represent the locations of the recordings and edges are determined using cross-covariance time-delay estimation method. The algorithm identifies rotational activity, spreading from vertex to vertex creating a cycle. This work is a simulation study and it uses a highly detailed computational 3D model of human atria in which sustained rotor activation of the atria was achieved. Virtual electrodes were placed on the endocardial surface, and EGMs were calculated at each of these electrodes. The propagation of the electric wave fronts in the atrial myocardium during AF is very complex, so in order to properly capture wave propagation patterns, we split EGMs into multiple short time frames. Then, a specific network for each of these time frames was generated, and the cycles repeating in consecutive networks point us to the stable rotor's location. The respective atrial voltage map served as reference. By detecting a cycle between the same 3 nodes in 19 out of 58 networks, where 10 of these networks were in consecutive time frames, a stable rotor was successfully located.

Directed Network Mapping Approach to Rotor Localization in Atrial Fibrillation Simulation / M. Vila, S. Rocher, M.W. Rivolta, J. Saiz, R. Sassi (ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY). - In: 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)[s.l] : IEEE, 2021. - ISBN 978-1-7281-1179-7. - pp. 730-733 (( Intervento presentato al 43. convegno Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) tenutosi a on line nel 2021 [10.1109/EMBC46164.2021.9629911].

Directed Network Mapping Approach to Rotor Localization in Atrial Fibrillation Simulation

M. Vila
Primo
;
M.W. Rivolta;R. Sassi
Ultimo
2021

Abstract

Catheter ablation for atrial fibrillation (AF) is one of the most commonly performed electrophysiology procedures. Despite significant advances in our understanding of AF mechanisms in the last years, ablation outcomes remain suboptimal for many patients, particularly those with persistent or long-standing AF. A possible reason is that ablation techniques mainly focus on anatomic, rather than patient-specific functional targets for ablation. The identification of such ablation targets remains challenging. The purpose of this study is to investigate a novel approach based on directed networks, which allow the automatic detection of important arrhythmia mechanisms, that can be convenient for guiding the ablation strategy. The networks are generated by processing unipolar electrograms (EGMs) collected by the catheters positioned at the different regions of the atria. Network vertices represent the locations of the recordings and edges are determined using cross-covariance time-delay estimation method. The algorithm identifies rotational activity, spreading from vertex to vertex creating a cycle. This work is a simulation study and it uses a highly detailed computational 3D model of human atria in which sustained rotor activation of the atria was achieved. Virtual electrodes were placed on the endocardial surface, and EGMs were calculated at each of these electrodes. The propagation of the electric wave fronts in the atrial myocardium during AF is very complex, so in order to properly capture wave propagation patterns, we split EGMs into multiple short time frames. Then, a specific network for each of these time frames was generated, and the cycles repeating in consecutive networks point us to the stable rotor's location. The respective atrial voltage map served as reference. By detecting a cycle between the same 3 nodes in 19 out of 58 networks, where 10 of these networks were in consecutive time frames, a stable rotor was successfully located.
Computer Simulation; Electrophysiologic Techniques, Cardiac; Heart Atria; Humans; Atrial Fibrillation; Catheter Ablation
Settore INF/01 - Informatica
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
   MutlidisciplinarY training network for ATrial fibRillation monItoring, treAtment and progression
   MY-ATRIA
   EUROPEAN COMMISSION
   H2020
2021
IEEE
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
EMBC_2021___Locating_Rotors_using_Directed_Networks_in_AF.pdf

accesso aperto

Descrizione: Postscript del paper.
Tipologia: Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione 3.46 MB
Formato Adobe PDF
3.46 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/906828
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact