OBJECTIVES: The Florida-sleeve is a valve-sparing technique that causes minimal interference to leaflet kinematics and aortic root dynamism. The aim of this in vitro study was to evaluate the effects of the Florida-sleeve and Yacoub techniques on aortic leaflet kinematics. METHODS: Two groups of 6 whole porcine hearts were treated with either the Florida-sleeve technique or the Yacoub technique and tested in a pulsatile loop. Valve fluid dynamics, coronary flow analysis and valve echocardiograms were performed both before and after the procedures. RESULTS: Both procedures showed no difference in rapid valve opening time as compared with their respective baseline values. The Florida-sleeve procedure showed a shorter slow closing time (192 ± 19 ms vs baseline 244 ± 14 ms, P = 0.016) and increased slow closing velocity (-1.5 ± 0.4 cm/s vs baseline -0.8 ± 0.4 cm/s, P = 0.038). In the rapid valve closing phase, the Yacoub procedure showed a trend towards slower closing valve velocity (-16 ± 9 cm/s vs baseline -25 ± 9 cm/s, P = 0.07). The Yacoub procedure showed larger leaflet displacement at the end of the slow valve closing time that was 2.0 ± 0.5 cm vs baseline 1.5 ± 0.3 cm, P = 0.044. When comparing the Florida-sleeve and Yacoub procedures, the former showed statistically significant shorter slow valve closing time (P = 0.017). CONCLUSIONS: This study showed that the Florida-sleeve technique alters the slow closing phase of the aortic valve leaflet kinematics when compared with both the normal baseline and Yacoub procedure, while the latter showed a larger leaflet displacement before the rapid closing valve phase.

Leaflet kinematics after the Yacoub and Florida-sleeve operations: Results of an in vitro study / G. Tasca, M. Jaworek, F. Lucherini, F. Trinca, P. Redaelli, C. Antona, R. Vismara. - In: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY. - ISSN 1010-7940. - 59:3(2021), pp. 674-679. [10.1093/ejcts/ezaa370]

Leaflet kinematics after the Yacoub and Florida-sleeve operations: Results of an in vitro study

C. Antona
Penultimo
;
2021

Abstract

OBJECTIVES: The Florida-sleeve is a valve-sparing technique that causes minimal interference to leaflet kinematics and aortic root dynamism. The aim of this in vitro study was to evaluate the effects of the Florida-sleeve and Yacoub techniques on aortic leaflet kinematics. METHODS: Two groups of 6 whole porcine hearts were treated with either the Florida-sleeve technique or the Yacoub technique and tested in a pulsatile loop. Valve fluid dynamics, coronary flow analysis and valve echocardiograms were performed both before and after the procedures. RESULTS: Both procedures showed no difference in rapid valve opening time as compared with their respective baseline values. The Florida-sleeve procedure showed a shorter slow closing time (192 ± 19 ms vs baseline 244 ± 14 ms, P = 0.016) and increased slow closing velocity (-1.5 ± 0.4 cm/s vs baseline -0.8 ± 0.4 cm/s, P = 0.038). In the rapid valve closing phase, the Yacoub procedure showed a trend towards slower closing valve velocity (-16 ± 9 cm/s vs baseline -25 ± 9 cm/s, P = 0.07). The Yacoub procedure showed larger leaflet displacement at the end of the slow valve closing time that was 2.0 ± 0.5 cm vs baseline 1.5 ± 0.3 cm, P = 0.044. When comparing the Florida-sleeve and Yacoub procedures, the former showed statistically significant shorter slow valve closing time (P = 0.017). CONCLUSIONS: This study showed that the Florida-sleeve technique alters the slow closing phase of the aortic valve leaflet kinematics when compared with both the normal baseline and Yacoub procedure, while the latter showed a larger leaflet displacement before the rapid closing valve phase.
Adult; Aortic valve sparing; Leaflet kinematics; Animals; Aorta; Aortic Valve; Biomechanical Phenomena; Florida; Swine; Aortic Valve Insufficiency; Heart Valve Prosthesis
Settore MED/23 - Chirurgia Cardiaca
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
ezaa370.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 560.47 kB
Formato Adobe PDF
560.47 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/904548
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact