The implant primary stability is a fundamental condition for avoiding implant micro-motions that might result in fibrous encapsulation; its achievement is facilitated by macro- and micro-geometry of the implant, and by the bone density and architecture at the intended implant site. The aim was to evaluate an osteocondensing drilling protocol for dental implant positioning compared to standard protocol on polyurethane block. A total of 40 implants, 20 for each osteocondensing group (Test) and 20 for standard drilling group (Control), were positioned. Insertion torque (IT), removal torque (RT), and Periotest were measured. A IT, RT, and Periotest significant difference was present in favor of the implant osteocondensing protocol. The results suggested that osteocondensing protocol represents a useful technique for implant placement in poor density bone.
Implant primary stability with an osteocondensation drilling protocol in different density polyurethane blocks / S. Fanali, M. Tumedei, P. Pignatelli, F. Inchingolo, P. Pennacchietti, G. Pace, A. Piattelli. - In: COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING. - ISSN 1025-5842. - 24:1(2021), pp. 14-20. [10.1080/10255842.2020.1806251]
Implant primary stability with an osteocondensation drilling protocol in different density polyurethane blocks
M. Tumedei
;
2021
Abstract
The implant primary stability is a fundamental condition for avoiding implant micro-motions that might result in fibrous encapsulation; its achievement is facilitated by macro- and micro-geometry of the implant, and by the bone density and architecture at the intended implant site. The aim was to evaluate an osteocondensing drilling protocol for dental implant positioning compared to standard protocol on polyurethane block. A total of 40 implants, 20 for each osteocondensing group (Test) and 20 for standard drilling group (Control), were positioned. Insertion torque (IT), removal torque (RT), and Periotest were measured. A IT, RT, and Periotest significant difference was present in favor of the implant osteocondensing protocol. The results suggested that osteocondensing protocol represents a useful technique for implant placement in poor density bone.File | Dimensione | Formato | |
---|---|---|---|
CM IN BIOM AND BIOMED ENGIN-Fanali 2020.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
1.76 MB
Formato
Adobe PDF
|
1.76 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.