The dental implant primary stability and micromovement absence represent critical factor for dental implant osseointegration. The aim of the present in vitro investigation was to simulate the bone response on different polyurethane densities the effect of self-tapping threads and round apex implant geometry. A total of 40 implants were positioned in D1, D2, D3 and D4 polyurethane block densities following a calibrated drilling protocol. The Insertion, removal Torque and resonance frequency analysis (RFA) means were calculated. All experimental conditions showed insertion torque values >30 Ncm. A significant higher insertion torque, removal and RFA was present in D1 polyurethane. Similar evidences were evidenced for D3 and D4. The effectiveness of the present study suggested a valuable clinical advantage for self-tapping threads and round apex implant using, such as in case of reduced bone density in the posterior maxilla.

An in vitro evaluation on polyurethane foam sheets of the insertion torque, removal torque values, and resonance frequency analysis (RFA) of a self-tapping threads and round apex implant / M. Tumedei, A. Piattelli, A. Falco, F. De Angelis, F. Lorusso, M. Di Carmine, G. Iezzi. - In: CELLULAR POLYMERS. - ISSN 0262-4893. - 40:1(2021), pp. 20-30. [10.1177/0262489320971796]

An in vitro evaluation on polyurethane foam sheets of the insertion torque, removal torque values, and resonance frequency analysis (RFA) of a self-tapping threads and round apex implant

M. Tumedei
Primo
;
2021

Abstract

The dental implant primary stability and micromovement absence represent critical factor for dental implant osseointegration. The aim of the present in vitro investigation was to simulate the bone response on different polyurethane densities the effect of self-tapping threads and round apex implant geometry. A total of 40 implants were positioned in D1, D2, D3 and D4 polyurethane block densities following a calibrated drilling protocol. The Insertion, removal Torque and resonance frequency analysis (RFA) means were calculated. All experimental conditions showed insertion torque values >30 Ncm. A significant higher insertion torque, removal and RFA was present in D1 polyurethane. Similar evidences were evidenced for D3 and D4. The effectiveness of the present study suggested a valuable clinical advantage for self-tapping threads and round apex implant using, such as in case of reduced bone density in the posterior maxilla.
Dental implant; polyurethane blocks; primary stability
Settore MED/50 - Scienze Tecniche Mediche Applicate
Settore MED/28 - Malattie Odontostomatologiche
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
Cellular Polymers.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 679.15 kB
Formato Adobe PDF
679.15 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
0262489320971796.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 648.18 kB
Formato Adobe PDF
648.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/896560
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact