Background: Experimental and pilot clinical data suggest that spontaneously breathing patients with sepsis and septic shock may present increased respiratory drive and effort, even in the absence of pulmonary infection. The study hypothesis was that respiratory drive and effort may be increased in septic patients and correlated with extrapulmonary determinant and that high-flow nasal cannula may modulate drive and effort. Methods: Twenty-five nonintubated patients with extrapulmonary sepsis or septic shock were enrolled. Each patient underwent three consecutive steps: low-flow oxygen at baseline, high-flow nasal cannula, and then low-flow oxygen again. Arterial blood gases, esophageal pressure, and electrical impedance tomography data were recorded toward the end of each step. Respiratory effort was measured as the negative swing of esophageal pressure (Delta P-es); drive was quantified as the change in esophageal pressure during the first 500 ms from start of inspiration (P-0.5). Dynamic lung compliance was calculated as the tidal volume measured by electrical impedance tomography, divided by Delta P-es. The results are presented as medians [25th to 75th percentile]. Results: Thirteen patients (52%) were in septic shock. The Sequential Organ Failure Assessment score was 5 [4 to 9]. During low-flow oxygen at baseline, respiratory drive and effort were elevated and significantly correlated with arterial lactate (r = 0.46, P = 0.034) and inversely with dynamic lung compliance (r = -0.735, P < 0.001). Noninvasive support by high-flow nasal cannula induced a significant decrease of respiratory drive (P-0.5: 6.0 [4.4 to 9.0] vs. 4.3 [3.5 to 6.6] vs. 6.6 [4.9 to 10.7] cm H2O, P < 0.001) and effort (Delta P-es: 8.0 [6.0 to 11.5] vs. 5.5 [4.5 to 8.0] vs. 7.5 [6.0 to 12.6] cm H2O, P < 0.001). Oxygenation and arterial carbon dioxide levels remained stable during all study phases. Conclusions: Patients with sepsis and septic shock of extrapulmonary origin present elevated respiratory drive and effort, which can be effectively reduced by high-flow nasal cannula.

Respiratory Drive in Patients with Sepsis and Septic Shock: Modulation by High-flow Nasal Cannula / T. Mauri, E. Spinelli, B. Pavlovsky, D.L. Grieco, I. Ottaviani, M.C. Basile, F. Dalla Corte, G. Pintaudi, E. Garofalo, A. Rundo, C.A. Volta, A. Pesenti, S. Spadaro. - In: ANESTHESIOLOGY. - ISSN 0003-3022. - 135:6(2021), pp. 1066-1075. [10.1097/ALN.0000000000004010]

Respiratory Drive in Patients with Sepsis and Septic Shock: Modulation by High-flow Nasal Cannula

T. Mauri
Primo
;
M.C. Basile;A. Pesenti;
2021

Abstract

Background: Experimental and pilot clinical data suggest that spontaneously breathing patients with sepsis and septic shock may present increased respiratory drive and effort, even in the absence of pulmonary infection. The study hypothesis was that respiratory drive and effort may be increased in septic patients and correlated with extrapulmonary determinant and that high-flow nasal cannula may modulate drive and effort. Methods: Twenty-five nonintubated patients with extrapulmonary sepsis or septic shock were enrolled. Each patient underwent three consecutive steps: low-flow oxygen at baseline, high-flow nasal cannula, and then low-flow oxygen again. Arterial blood gases, esophageal pressure, and electrical impedance tomography data were recorded toward the end of each step. Respiratory effort was measured as the negative swing of esophageal pressure (Delta P-es); drive was quantified as the change in esophageal pressure during the first 500 ms from start of inspiration (P-0.5). Dynamic lung compliance was calculated as the tidal volume measured by electrical impedance tomography, divided by Delta P-es. The results are presented as medians [25th to 75th percentile]. Results: Thirteen patients (52%) were in septic shock. The Sequential Organ Failure Assessment score was 5 [4 to 9]. During low-flow oxygen at baseline, respiratory drive and effort were elevated and significantly correlated with arterial lactate (r = 0.46, P = 0.034) and inversely with dynamic lung compliance (r = -0.735, P < 0.001). Noninvasive support by high-flow nasal cannula induced a significant decrease of respiratory drive (P-0.5: 6.0 [4.4 to 9.0] vs. 4.3 [3.5 to 6.6] vs. 6.6 [4.9 to 10.7] cm H2O, P < 0.001) and effort (Delta P-es: 8.0 [6.0 to 11.5] vs. 5.5 [4.5 to 8.0] vs. 7.5 [6.0 to 12.6] cm H2O, P < 0.001). Oxygenation and arterial carbon dioxide levels remained stable during all study phases. Conclusions: Patients with sepsis and septic shock of extrapulmonary origin present elevated respiratory drive and effort, which can be effectively reduced by high-flow nasal cannula.
Aged; Cohort Studies; Electric Impedance; Female; Humans; Intensive Care Units; Male; Middle Aged; Oxygen Inhalation Therapy; Respiratory Insufficiency; Respiratory Rate; Sepsis; Shock, Septic; Cannula
Settore MED/41 - Anestesiologia
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
559_mauri_anesthesiology_20211200.0-00024.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 672.8 kB
Formato Adobe PDF
672.8 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/892668
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 11
social impact