Surgeons who introduce intraoperative neural monitoring (IONM) or a new IONM accessory, or related procedure in their practice should have completed relevant surgical training, possess operating privileges in the affected endocrine system, and be able to address anticipated complications. Surgeon responsibility in monitoring is dual component. First, technical component is using and setting up the IONM equipment correctly and understanding the inherent properties of the system to avoid an erroneous setup (e.g., no muscle relaxation, correct electrode placement, low impedance, etc.). Second, interpretive component is performing the monitoring able to distinguish between a true response versus an artifactual one. Organizations such as the International Neural Study Group and the Korean Intraoperative Neural Monitoring Society provide training courses for surgeon, as well as a means to certify levels of monitoring interpretative competence.
Intraoperative Neural Monitoring in Thyroid Surgery : Role and Responsibility of Surgeon / H. Yub Kim, R.P. Tufano, Y. Jun Chai, M. Barczynski, Ö. Makay, C. Wu, E. Berber, H. Sun, G. Dionigi. - In: JOURNAL OF ENDOCRINE SURGERY. - ISSN 2508-8149. - 18:1(2018), pp. 49-60. [10.16956/jes.2018.18.1.49]
Intraoperative Neural Monitoring in Thyroid Surgery : Role and Responsibility of Surgeon
G. Dionigi
Ultimo
2018
Abstract
Surgeons who introduce intraoperative neural monitoring (IONM) or a new IONM accessory, or related procedure in their practice should have completed relevant surgical training, possess operating privileges in the affected endocrine system, and be able to address anticipated complications. Surgeon responsibility in monitoring is dual component. First, technical component is using and setting up the IONM equipment correctly and understanding the inherent properties of the system to avoid an erroneous setup (e.g., no muscle relaxation, correct electrode placement, low impedance, etc.). Second, interpretive component is performing the monitoring able to distinguish between a true response versus an artifactual one. Organizations such as the International Neural Study Group and the Korean Intraoperative Neural Monitoring Society provide training courses for surgeon, as well as a means to certify levels of monitoring interpretative competence.| File | Dimensione | Formato | |
|---|---|---|---|
|
jes-18-e4.pdf
accesso aperto
Tipologia:
Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione
1.79 MB
Formato
Adobe PDF
|
1.79 MB | Adobe PDF | Visualizza/Apri |
|
1219JES_jes-18-49.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
1.76 MB
Formato
Adobe PDF
|
1.76 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.