Objectives/Hypothesis: During intraoperative neuromonitoring in thyroid surgery, two different kinds of stimulator probes, monopolar and bipolar, are commonly used to stimulate the laryngeal nerves. We explore the unique characteristics of both of these probes as they relate to intraoperative laryngeal nerve mapping. Methods: Twenty-one patients undergoing neuromonitored thyroidectomy by a single surgeon were enrolled. Electromyography (EMG) amplitude and latency measurements were prospectively recorded concurrently from 1 mA stimulation of vagus nerve (VN) and inferior/superior recurrent laryngeal nerve before (with and without fascia) and after thyroid resection using bipolar and monopolar stimulator probes. Results: Significantly higher amplitudes were obtained with monopolar stimulator probes as compared to bipolar probes, in several stimulation scenarios such as at right VN pre-resection (carotid sheath intact), right VN pre-resection (carotid sheath dissected), right VN post-resection and left VN (carotid sheath dissected). No significant differences were found between amplitudes and latency values in all other stimulation scenarios. Conclusions: According to this study, both probes are reliable and safe for neural mapping. The kind of probe used during neural monitoring is based on surgical situations and surgeon preference. Level of Evidence: 3 (According to Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence) Laryngoscope, 131:E2718–E2726, 2021.

Comparison of Monopolar and Bipolar Stimulator Probes for Intraoperative Nerve Mapping During Thyroidectomy : A Prospective Study / Y. Turk, O. Makay, D. Kamani, O. Okose, I.J. Behr, M. Ozdemir, G. Icoz, M. Akyildiz, G. Dionigi, A.H. Abdelhamid Ahmed, G.W. Randolph. - In: LARYNGOSCOPE. - ISSN 0023-852X. - 131:10(2021), pp. E2718-E2726. [10.1002/lary.29804]

Comparison of Monopolar and Bipolar Stimulator Probes for Intraoperative Nerve Mapping During Thyroidectomy : A Prospective Study

G. Dionigi;
2021

Abstract

Objectives/Hypothesis: During intraoperative neuromonitoring in thyroid surgery, two different kinds of stimulator probes, monopolar and bipolar, are commonly used to stimulate the laryngeal nerves. We explore the unique characteristics of both of these probes as they relate to intraoperative laryngeal nerve mapping. Methods: Twenty-one patients undergoing neuromonitored thyroidectomy by a single surgeon were enrolled. Electromyography (EMG) amplitude and latency measurements were prospectively recorded concurrently from 1 mA stimulation of vagus nerve (VN) and inferior/superior recurrent laryngeal nerve before (with and without fascia) and after thyroid resection using bipolar and monopolar stimulator probes. Results: Significantly higher amplitudes were obtained with monopolar stimulator probes as compared to bipolar probes, in several stimulation scenarios such as at right VN pre-resection (carotid sheath intact), right VN pre-resection (carotid sheath dissected), right VN post-resection and left VN (carotid sheath dissected). No significant differences were found between amplitudes and latency values in all other stimulation scenarios. Conclusions: According to this study, both probes are reliable and safe for neural mapping. The kind of probe used during neural monitoring is based on surgical situations and surgeon preference. Level of Evidence: 3 (According to Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence) Laryngoscope, 131:E2718–E2726, 2021.
Bipolar probe; intraoperative neuromonitoring; monopolar probe; neural mapping; thyroidectomy; Adult; Aged; Electric Stimulation; Electromyography; Equipment Design; Female; Humans; Male; Middle Aged; Monitoring, Intraoperative; Prospective Studies; Recurrent Laryngeal Nerve; Vagus Nerve; Thyroidectomy
Settore MED/18 - Chirurgia Generale
2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
turk2021.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 940.38 kB
Formato Adobe PDF
940.38 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
lary.29804.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/878067
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact