Background: The European Society for Medical Oncology-Magnitude of Clinical Benefit Scale (ESMO-MCBS) is a validated, widely used tool developed to score the clinical benefit from cancer medicines reported in clinical trials. ESMO-MCBS scores assume valid research methodologies and quality trial implementation. Studies incorporating flawed design, implementation, or data analysis may generate outcomes that exaggerate true benefit and are not generalisable. Failure to either indicate or penalise studies with bias undermines the intention and diminishes the integrity of ESMO-MCBS scores. This review aimed to evaluate the adequacy of the ESMO-MCBS to address bias generated by flawed design, implementation, or data analysis and identify shortcomings in need of amendment. Methods: As part of a refinement of the ESMO-MCBS, we reviewed trial design, implementation, and data analysis issues that could bias the results. For each issue of concern, we reviewed the ESMO-MCBS v1.1 approach against standards derived from Helsinki guidelines for ethical human research and guidelines from the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use, the Food and Drugs Administration, the European Medicines Agency, and European Network for Health Technology Assessment. Results: Six design, two implementation, and two data analysis and interpretation issues were evaluated and in three, the ESMO-MCBS provided adequate protections. Seven shortcomings in the ability of the ESMO-MCBS to identify and address bias were identified. These related to (i) evaluation of the control arm, (ii) crossover issues, (iii) criteria for non-inferiority, (iv) substandard post-progression treatment, (v) post hoc subgroup findings based on biomarkers, (vi) informative censoring, and (vii) publication bias against quality-of-life data. Conclusion: Interpretation of the ESMO-MCBS scores requires critical appraisal of trials to understand caveats in trial design, implementation, and data analysis that may have biased results and conclusions. These will be addressed in future iterations of the ESMO-MCBS.

Biases in study design, implementation, and data analysis that distort the appraisal of clinical benefit and ESMO-Magnitude of Clinical Benefit Scale (ESMO-MCBS) scoring / B. Gyawali, E.G.E. de Vries, U. Dafni, T. Amaral, J. Barriuso, J. Bogaerts, A. Calles, G. Curigliano, C. Gomez-Roca, B. Kiesewetter, S. Oosting, A. Passaro, G. Pentheroudakis, M. Piccart, F. Roitberg, J. Tabernero, N. Tarazona, D. Trapani, R. Wester, G. Zarkavelis, C. Zielinski, P. Zygoura, N.I. Cherny. - In: ESMO OPEN. - ISSN 2059-7029. - 6:3(2021 Apr 19).

Biases in study design, implementation, and data analysis that distort the appraisal of clinical benefit and ESMO-Magnitude of Clinical Benefit Scale (ESMO-MCBS) scoring

G. Curigliano
Conceptualization
;
D. Trapani;
2021

Abstract

Background: The European Society for Medical Oncology-Magnitude of Clinical Benefit Scale (ESMO-MCBS) is a validated, widely used tool developed to score the clinical benefit from cancer medicines reported in clinical trials. ESMO-MCBS scores assume valid research methodologies and quality trial implementation. Studies incorporating flawed design, implementation, or data analysis may generate outcomes that exaggerate true benefit and are not generalisable. Failure to either indicate or penalise studies with bias undermines the intention and diminishes the integrity of ESMO-MCBS scores. This review aimed to evaluate the adequacy of the ESMO-MCBS to address bias generated by flawed design, implementation, or data analysis and identify shortcomings in need of amendment. Methods: As part of a refinement of the ESMO-MCBS, we reviewed trial design, implementation, and data analysis issues that could bias the results. For each issue of concern, we reviewed the ESMO-MCBS v1.1 approach against standards derived from Helsinki guidelines for ethical human research and guidelines from the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use, the Food and Drugs Administration, the European Medicines Agency, and European Network for Health Technology Assessment. Results: Six design, two implementation, and two data analysis and interpretation issues were evaluated and in three, the ESMO-MCBS provided adequate protections. Seven shortcomings in the ability of the ESMO-MCBS to identify and address bias were identified. These related to (i) evaluation of the control arm, (ii) crossover issues, (iii) criteria for non-inferiority, (iv) substandard post-progression treatment, (v) post hoc subgroup findings based on biomarkers, (vi) informative censoring, and (vii) publication bias against quality-of-life data. Conclusion: Interpretation of the ESMO-MCBS scores requires critical appraisal of trials to understand caveats in trial design, implementation, and data analysis that may have biased results and conclusions. These will be addressed in future iterations of the ESMO-MCBS.
ESMO-MCBS; bias; clinical trial analysis; clinical trial design; clinical trial implementation; clinical trial reporting
Settore MED/06 - Oncologia Medica
Article (author)
File in questo prodotto:
File Dimensione Formato  
Bias in study Design Curigliano 2021.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 490.07 kB
Formato Adobe PDF
490.07 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Caricamento pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/839591
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 17
social impact