Inelastic compression (IC) has been proposed as a therapeutic option in the management of breast cancer-related lymphedema (BCRL). To date, no studies have investigated the reliability of IC in the rehabilitative management of BCRL. Thus, we aimed at evaluating the safety and tolerability of an instantly adjustable IC device for BCRL patients. We included BCRL patients referred to an Oncological Rehabilitation Unit. They were subjected to complex decongestion therapy using a self-adaptive IC device. The primary outcome was safety and tolerability of IC in the rehabilitation treatment of BCRL patients. Secondary outcomes were: BCRL volume modifications; disability; quality of life; IC application time. Outcomes were assessed at the baseline (T0), at the end of the 2-week rehabilitation treatment (T1), and at 1 month (T2). Nine BCRL women, mean aged 56.7 ± 4.4 years, were enrolled. None showed side effects, except for a low discomfort and moderate swelling reported by 1 patient (11.1%). BCRL volume significantly reduced at T1 (p = 0.001) with a positive trend at T2. IC timing was significantly reduced at T1 (p = 0.035) and T2 (p = 0.003). Taken together, these findings suggested that IC could be considered as a safe, well-tolerated, and effective tool in the rehabilitative management of BCRL patients.

Lymphedema rehabilitation using self-adaptive inelastic compression in breast cancer: A proof-of-principle study / A. de Sire, N. Fusco, E. Sajjadi, L. Lippi, C. Cisari, M. Invernizzi. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 11:4(2021 Feb 22), pp. 1901.1-1901.8. [10.3390/app11041901]

Lymphedema rehabilitation using self-adaptive inelastic compression in breast cancer: A proof-of-principle study

N. Fusco
Secondo
;
E. Sajjadi;
2021

Abstract

Inelastic compression (IC) has been proposed as a therapeutic option in the management of breast cancer-related lymphedema (BCRL). To date, no studies have investigated the reliability of IC in the rehabilitative management of BCRL. Thus, we aimed at evaluating the safety and tolerability of an instantly adjustable IC device for BCRL patients. We included BCRL patients referred to an Oncological Rehabilitation Unit. They were subjected to complex decongestion therapy using a self-adaptive IC device. The primary outcome was safety and tolerability of IC in the rehabilitation treatment of BCRL patients. Secondary outcomes were: BCRL volume modifications; disability; quality of life; IC application time. Outcomes were assessed at the baseline (T0), at the end of the 2-week rehabilitation treatment (T1), and at 1 month (T2). Nine BCRL women, mean aged 56.7 ± 4.4 years, were enrolled. None showed side effects, except for a low discomfort and moderate swelling reported by 1 patient (11.1%). BCRL volume significantly reduced at T1 (p = 0.001) with a positive trend at T2. IC timing was significantly reduced at T1 (p = 0.035) and T2 (p = 0.003). Taken together, these findings suggested that IC could be considered as a safe, well-tolerated, and effective tool in the rehabilitative management of BCRL patients.
Breast cancer; Breast cancer-related lymphedema; Inelastic compression; Lymphedema; Quality of life; Rehabilitation
Settore MED/08 - Anatomia Patologica
Settore MED/34 - Medicina Fisica e Riabilitativa
22-feb-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
[2021] applsci-11-01901 BCRL.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 499.65 kB
Formato Adobe PDF
499.65 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/828153
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 13
social impact