Objective: Echo intensity measurements are highly influenced by ultrasound system and parameters used for measurement, making comparisons of results obtained from different ultrasound machines difficult. Therefore, it is necessary to understand how reliability changes when using different ultrasound systems and parameters. Materials and Methods: ALOKA SSD4000 and GE LOGIQ P6 systems were used to compare rectus femoris echo intensity in 16 healthy young subjects (eight women) using different depths (D), gains (G), and frequencies (F). The following settings were adopted: ALOKA1 (D6/G30/F7.5), ALOKA2 (D6/G45/F7.5), ALOKA3 (D6/G30/F10), LOGIQ1 (D6/G50/F15), LOGIQ2 (D6/G0/F15), LOGIQ3 (D6/G0/F10), and LOGIQ4 (D6/G30/F10). Intraclass correlation coefficient, standard error of the measure, minimum difference, and Bland-Altman tests were performed to calculate reliability and agreement between systems’ settings. Results: ALOKA1 × LOGIQ1, ALOKA1 × LOGIQ4, and ALOKA3 × LOGIQ1 showed moderate to high ICCs and agreement on the Bland-Altman test. Conclusion: Echo intensity varies between systems and parameters, but reliability can be increased by adjusting the ultrasound settings.

Echo Intensity Reliability From Two Ultrasound Systems / R. Rabello da Silva, K.D. Pompeo, I. de Almeida Paz, F.J. Lanferdini, R.S. Pinto, M.A. Vaz. - In: JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY. - ISSN 8756-4793. - 36:5(2020), pp. 464-469. [10.1177/8756479320929030]

Echo Intensity Reliability From Two Ultrasound Systems

R. Rabello da Silva;
2020

Abstract

Objective: Echo intensity measurements are highly influenced by ultrasound system and parameters used for measurement, making comparisons of results obtained from different ultrasound machines difficult. Therefore, it is necessary to understand how reliability changes when using different ultrasound systems and parameters. Materials and Methods: ALOKA SSD4000 and GE LOGIQ P6 systems were used to compare rectus femoris echo intensity in 16 healthy young subjects (eight women) using different depths (D), gains (G), and frequencies (F). The following settings were adopted: ALOKA1 (D6/G30/F7.5), ALOKA2 (D6/G45/F7.5), ALOKA3 (D6/G30/F10), LOGIQ1 (D6/G50/F15), LOGIQ2 (D6/G0/F15), LOGIQ3 (D6/G0/F10), and LOGIQ4 (D6/G30/F10). Intraclass correlation coefficient, standard error of the measure, minimum difference, and Bland-Altman tests were performed to calculate reliability and agreement between systems’ settings. Results: ALOKA1 × LOGIQ1, ALOKA1 × LOGIQ4, and ALOKA3 × LOGIQ1 showed moderate to high ICCs and agreement on the Bland-Altman test. Conclusion: Echo intensity varies between systems and parameters, but reliability can be increased by adjusting the ultrasound settings.
frequency; gain; gray-scale; muscle quality; reliability
Settore BIO/16 - Anatomia Umana
2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
Rabello et al. 2020 - JDMS.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 487.63 kB
Formato Adobe PDF
487.63 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/816918
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact