Introduction: The ultrasound technique has been extensively used to measure echo intensity, with the goal of measuring muscle quality, muscle damage, or to detect neuromuscular disorders. However, it is not clear how reliable the technique is when comparing different days, raters, and analysts, or if the reliability is affected by the muscle site where the image is obtained from. The goal of this study was to compare the intra-rater, inter-rater, and inter-analyst reliability of ultrasound measurements obtained from two different sites at the rectus femoris muscle. Methods: Muscle echo intensity was quantified from ultrasound images acquired at 50% [RF50] and at 70% [RF70] of the thigh length in 32 healthy subjects. Results: Echo intensity values were higher (p = 0.0001) at RF50 (61.08 ± 12.04) compared to RF70 (57.32 ± 12.58). Reliability was high in both RF50 and RF70 for all comparisons: intra-rater (ICC = 0.89 and 0.94), inter-rater (ICC = 0.89 and 0.89), and inter-analyst (ICC = 0.98 and 0.99), respectively. However, there were differences (p < 0.05) between raters and analysts when obtaining/analyzing echo intensity values in both rectus femoris sites. Conclusions: The differences in echo intensity values between positions suggest that rectus femoris's structure is not homogeneous, and therefore measurements from different muscle regions should not be used interchangeably. Both sites showed a high reliability, meaning that the measure is accurate if performed by the same experienced rater in different days, if performed by different experienced raters in the same day, and if analyzed by different well-trained analysts, regardless of the evaluated muscle site.

Echo intensity reliability between two rectus femoris probe sites / R. Rabello da Silva, M. Frohlich, A.F. Bueno, M.A.Z. Marcolino, T. De Bona Bernardi, G. Sbruzzi, M. Aurelio Vaz. - In: ULTRASOUND. - ISSN 1742-271X. - 27:4(2019), pp. 233-240. [10.1177/1742271X19853859]

Echo intensity reliability between two rectus femoris probe sites

R. Rabello da Silva
Primo
;
2019

Abstract

Introduction: The ultrasound technique has been extensively used to measure echo intensity, with the goal of measuring muscle quality, muscle damage, or to detect neuromuscular disorders. However, it is not clear how reliable the technique is when comparing different days, raters, and analysts, or if the reliability is affected by the muscle site where the image is obtained from. The goal of this study was to compare the intra-rater, inter-rater, and inter-analyst reliability of ultrasound measurements obtained from two different sites at the rectus femoris muscle. Methods: Muscle echo intensity was quantified from ultrasound images acquired at 50% [RF50] and at 70% [RF70] of the thigh length in 32 healthy subjects. Results: Echo intensity values were higher (p = 0.0001) at RF50 (61.08 ± 12.04) compared to RF70 (57.32 ± 12.58). Reliability was high in both RF50 and RF70 for all comparisons: intra-rater (ICC = 0.89 and 0.94), inter-rater (ICC = 0.89 and 0.89), and inter-analyst (ICC = 0.98 and 0.99), respectively. However, there were differences (p < 0.05) between raters and analysts when obtaining/analyzing echo intensity values in both rectus femoris sites. Conclusions: The differences in echo intensity values between positions suggest that rectus femoris's structure is not homogeneous, and therefore measurements from different muscle regions should not be used interchangeably. Both sites showed a high reliability, meaning that the measure is accurate if performed by the same experienced rater in different days, if performed by different experienced raters in the same day, and if analyzed by different well-trained analysts, regardless of the evaluated muscle site.
grayscale analysis; inter-analyst; inter-rater; Intra-rater; reproducibility
Settore BIO/16 - Anatomia Umana
2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
Rabello et al. 2019.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 988.36 kB
Formato Adobe PDF
988.36 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
10.1177_1742271X19853859.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 989.02 kB
Formato Adobe PDF
989.02 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/816910
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact