Introduction: The ultrasound technique has been extensively used to measure echo intensity, with the goal of measuring muscle quality, muscle damage, or to detect neuromuscular disorders. However, it is not clear how reliable the technique is when comparing different days, raters, and analysts, or if the reliability is affected by the muscle site where the image is obtained from. The goal of this study was to compare the intra-rater, inter-rater, and inter-analyst reliability of ultrasound measurements obtained from two different sites at the rectus femoris muscle. Methods: Muscle echo intensity was quantified from ultrasound images acquired at 50% [RF50] and at 70% [RF70] of the thigh length in 32 healthy subjects. Results: Echo intensity values were higher (p = 0.0001) at RF50 (61.08 ± 12.04) compared to RF70 (57.32 ± 12.58). Reliability was high in both RF50 and RF70 for all comparisons: intra-rater (ICC = 0.89 and 0.94), inter-rater (ICC = 0.89 and 0.89), and inter-analyst (ICC = 0.98 and 0.99), respectively. However, there were differences (p < 0.05) between raters and analysts when obtaining/analyzing echo intensity values in both rectus femoris sites. Conclusions: The differences in echo intensity values between positions suggest that rectus femoris's structure is not homogeneous, and therefore measurements from different muscle regions should not be used interchangeably. Both sites showed a high reliability, meaning that the measure is accurate if performed by the same experienced rater in different days, if performed by different experienced raters in the same day, and if analyzed by different well-trained analysts, regardless of the evaluated muscle site.
Echo intensity reliability between two rectus femoris probe sites / R. Rabello da Silva, M. Frohlich, A.F. Bueno, M.A.Z. Marcolino, T. De Bona Bernardi, G. Sbruzzi, M. Aurelio Vaz. - In: ULTRASOUND. - ISSN 1742-271X. - 27:4(2019), pp. 233-240. [10.1177/1742271X19853859]
Echo intensity reliability between two rectus femoris probe sites
R. Rabello da SilvaPrimo
;
2019
Abstract
Introduction: The ultrasound technique has been extensively used to measure echo intensity, with the goal of measuring muscle quality, muscle damage, or to detect neuromuscular disorders. However, it is not clear how reliable the technique is when comparing different days, raters, and analysts, or if the reliability is affected by the muscle site where the image is obtained from. The goal of this study was to compare the intra-rater, inter-rater, and inter-analyst reliability of ultrasound measurements obtained from two different sites at the rectus femoris muscle. Methods: Muscle echo intensity was quantified from ultrasound images acquired at 50% [RF50] and at 70% [RF70] of the thigh length in 32 healthy subjects. Results: Echo intensity values were higher (p = 0.0001) at RF50 (61.08 ± 12.04) compared to RF70 (57.32 ± 12.58). Reliability was high in both RF50 and RF70 for all comparisons: intra-rater (ICC = 0.89 and 0.94), inter-rater (ICC = 0.89 and 0.89), and inter-analyst (ICC = 0.98 and 0.99), respectively. However, there were differences (p < 0.05) between raters and analysts when obtaining/analyzing echo intensity values in both rectus femoris sites. Conclusions: The differences in echo intensity values between positions suggest that rectus femoris's structure is not homogeneous, and therefore measurements from different muscle regions should not be used interchangeably. Both sites showed a high reliability, meaning that the measure is accurate if performed by the same experienced rater in different days, if performed by different experienced raters in the same day, and if analyzed by different well-trained analysts, regardless of the evaluated muscle site.File | Dimensione | Formato | |
---|---|---|---|
Rabello et al. 2019.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
988.36 kB
Formato
Adobe PDF
|
988.36 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
10.1177_1742271X19853859.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
989.02 kB
Formato
Adobe PDF
|
989.02 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.