Introduction: The aim of this study was to provide an external validation of bowel ultrasound (US) predictors of activity in ulcerative colitis (UC) and quantitative Milan Ultrasound Criteria (MUC). Methods: Forty-three consecutive patients with UC (16 in endoscopic remission and 27 with endoscopic activity) underwent bowel US and colonoscopy in a tertiary referral inflammatory bowel disease unit. Results: A MUC score >6.2 discriminated patients with active versus non-active UC with a sensitivity of 0.85 (95% confidence interval (CI) 0.66‒0.96), specificity of 0.94 (95% CI 0.70‒0.99) and an area under the curve of 0.902 (95% CI 0.772‒0.971) in complete agreement with the derivation study. Conclusion: The external validation of MUC confirms that it is an accurate tool for assessing disease activity in patients with UC.
Milan Ultrasound Criteria are accurate in assessing disease activity in ulcerative colitis: External validation / M. Allocca, E. Filippi, A. Costantino, S. Bonovas, G. Fiorino, F. Furfaro, L. Peyrin-Biroulet, M. Fraquelli, F. Caprioli, S. Danese. - In: UNITED EUROPEAN GASTROENTEROLOGY JOURNAL. - ISSN 2050-6406. - (2020). [Epub ahead of print]
Milan Ultrasound Criteria are accurate in assessing disease activity in ulcerative colitis: External validation
E. FilippiSecondo
;F. CaprioliPenultimo
;
2020
Abstract
Introduction: The aim of this study was to provide an external validation of bowel ultrasound (US) predictors of activity in ulcerative colitis (UC) and quantitative Milan Ultrasound Criteria (MUC). Methods: Forty-three consecutive patients with UC (16 in endoscopic remission and 27 with endoscopic activity) underwent bowel US and colonoscopy in a tertiary referral inflammatory bowel disease unit. Results: A MUC score >6.2 discriminated patients with active versus non-active UC with a sensitivity of 0.85 (95% confidence interval (CI) 0.66‒0.96), specificity of 0.94 (95% CI 0.70‒0.99) and an area under the curve of 0.902 (95% CI 0.772‒0.971) in complete agreement with the derivation study. Conclusion: The external validation of MUC confirms that it is an accurate tool for assessing disease activity in patients with UC.File | Dimensione | Formato | |
---|---|---|---|
2050640620980203.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
178.54 kB
Formato
Adobe PDF
|
178.54 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.