Background: Evidence on gadolinium brain accumulation after contrast-enhanced MRI prompted research in dose reduction. Purpose: To estimate accuracy and inter-reader reproducibility of tumor size measurement in breast MRI using 0.08 mmol/kg of gadobutrol. Methods: We retrospectively analyzed all women who underwent 1.5-T breast MRI for cancer staging at our department with 0.08 mmol/kg of gadobutrol. Two readers (R1 and R2, 12 and 3 years-experience) measured the largest lesion diameter. Accuracy was estimated both as correlation with pathology and rate of absolute (>5 mm) overestimation and underestimation, inter-reader reproducibility using the Bland-Altman method. Data are given as median and interquartile range. Results: Thirty-six patients were analyzed (median age 56 years, 49-66) for a total of 38 lesions, 24 (63%) mass enhancement, 14 (37%) non-mass enhancement. Histopathological median size (mm) of all lesions was 15 (9-25): 13 (9-19) for mass lesions, 19 (11-39) for non-mass lesions. On MRI, R1 measured (mm) 14 (10-22) for all lesions, 13 (10-19) for mass lesions, 19 (11-49) for non-mass lesions. MRI-pathology correlation was very high for all lesion categories (ρ ≥ 0.766). On MRI, R1 overestimated lesion size in 6 cases (16%), and underestimated in 3 (8%); R2, overestimated 7 cases (18%) and underestimated 3 cases (8%). At inter-reader reproducibility analysis (mm): bias 0.9, coefficient of reproducibility 13 for all lesions; -0.1 and 6 for mass lesions; 2.5 and 20 for non-mass lesions. Conclusions: Breast MRI may be performed using 0.08 mmol/kg of gadobutrol with high accuracy and acceptable inter-reader agreement.

Accuracy and inter-reader agreement of breast MRI for cancer staging using 0.08 mmol/kg of gadobutrol / A. Cozzi, G. Buragina, D. Spinelli, S. Schiaffino, M. Zanardo, G. Di Leo, L.A. Carbonaro, F. Sardanelli. - In: CLINICAL IMAGING. - ISSN 0899-7071. - 72(2021 Apr), pp. 154-161.

Accuracy and inter-reader agreement of breast MRI for cancer staging using 0.08 mmol/kg of gadobutrol

A. Cozzi
Co-primo
;
G. Buragina
Co-primo
;
D. Spinelli
Secondo
;
M. Zanardo;L.A. Carbonaro
Penultimo
;
F. Sardanelli
Ultimo
2021

Abstract

Background: Evidence on gadolinium brain accumulation after contrast-enhanced MRI prompted research in dose reduction. Purpose: To estimate accuracy and inter-reader reproducibility of tumor size measurement in breast MRI using 0.08 mmol/kg of gadobutrol. Methods: We retrospectively analyzed all women who underwent 1.5-T breast MRI for cancer staging at our department with 0.08 mmol/kg of gadobutrol. Two readers (R1 and R2, 12 and 3 years-experience) measured the largest lesion diameter. Accuracy was estimated both as correlation with pathology and rate of absolute (>5 mm) overestimation and underestimation, inter-reader reproducibility using the Bland-Altman method. Data are given as median and interquartile range. Results: Thirty-six patients were analyzed (median age 56 years, 49-66) for a total of 38 lesions, 24 (63%) mass enhancement, 14 (37%) non-mass enhancement. Histopathological median size (mm) of all lesions was 15 (9-25): 13 (9-19) for mass lesions, 19 (11-39) for non-mass lesions. On MRI, R1 measured (mm) 14 (10-22) for all lesions, 13 (10-19) for mass lesions, 19 (11-49) for non-mass lesions. MRI-pathology correlation was very high for all lesion categories (ρ ≥ 0.766). On MRI, R1 overestimated lesion size in 6 cases (16%), and underestimated in 3 (8%); R2, overestimated 7 cases (18%) and underestimated 3 cases (8%). At inter-reader reproducibility analysis (mm): bias 0.9, coefficient of reproducibility 13 for all lesions; -0.1 and 6 for mass lesions; 2.5 and 20 for non-mass lesions. Conclusions: Breast MRI may be performed using 0.08 mmol/kg of gadobutrol with high accuracy and acceptable inter-reader agreement.
Breast neoplasms; Contrast media; Magnetic resonance imaging; Reproducibility of results
Settore MED/36 - Diagnostica per Immagini e Radioterapia
apr-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0899707120304460-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.65 MB
Formato Adobe PDF
1.65 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/800608
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact