Renal hyperparathyroidism (RHPT) is one of the main complications in dogs affected with Chronic Kidney Disease (CKD). The measurement of serum parathyroid hormone (PTH) could be of clinical utility for the disease’s treatment and follow-up; however, PTH is not routinely determined due to limited available methods, often not fully validated in dogs. The aims of this study were the analytical validation of an immunoenzymatic method for the measurement of PTH in canine serum and the analysis of preliminary association of the obtained results with renal function. Twenty-six samples obtained from dogs healthy or affected with CKD were analysed. PTH was measured using a two-site immunoenzymometric human assay (ST AIA-PACK® Intact PTH, Tosoh Bioscience). The analytical validation protocol evaluated the assay precision and accuracy. Also, the PTH’s storage stability at 20◦ C, 4◦ C and −20◦ C was assessed. Clinical validation was performed by comparing PTH values with creatinine, phosphorus and International Renal Interest Society (IRIS) stage. The method showed optimal precision and accuracy, whereas stability was adequate up to 4 h at 20◦ C, 24 h at 4◦ C and 6 months at −20◦ C. PTH was positively associated with creatinine, phosphorus and IRIS stage. The investigated method was thus successfully validated in dogs, allowing its use for clinical purpose.
Analytical and clinical validation of a new immunoenzymatic method for the measurement of canine parathyroid hormone / J. Zambarbieri, F. Tagliasacchi, P. Moretti, A. Giordano, P. Scarpa. - In: ANIMALS. - ISSN 2076-2615. - 10:12(2020 Dec 17), pp. 2411.1-2411.11. [10.3390/ani10122411]
Analytical and clinical validation of a new immunoenzymatic method for the measurement of canine parathyroid hormone
J. Zambarbieri
;P. Moretti;A. Giordano;P. Scarpa
2020
Abstract
Renal hyperparathyroidism (RHPT) is one of the main complications in dogs affected with Chronic Kidney Disease (CKD). The measurement of serum parathyroid hormone (PTH) could be of clinical utility for the disease’s treatment and follow-up; however, PTH is not routinely determined due to limited available methods, often not fully validated in dogs. The aims of this study were the analytical validation of an immunoenzymatic method for the measurement of PTH in canine serum and the analysis of preliminary association of the obtained results with renal function. Twenty-six samples obtained from dogs healthy or affected with CKD were analysed. PTH was measured using a two-site immunoenzymometric human assay (ST AIA-PACK® Intact PTH, Tosoh Bioscience). The analytical validation protocol evaluated the assay precision and accuracy. Also, the PTH’s storage stability at 20◦ C, 4◦ C and −20◦ C was assessed. Clinical validation was performed by comparing PTH values with creatinine, phosphorus and International Renal Interest Society (IRIS) stage. The method showed optimal precision and accuracy, whereas stability was adequate up to 4 h at 20◦ C, 24 h at 4◦ C and 6 months at −20◦ C. PTH was positively associated with creatinine, phosphorus and IRIS stage. The investigated method was thus successfully validated in dogs, allowing its use for clinical purpose.File | Dimensione | Formato | |
---|---|---|---|
PTH animals-10-02411(1).pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
1.17 MB
Formato
Adobe PDF
|
1.17 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.