Creatinine in human serum was separated in a fused-silica capillary with H3PO4 (75 mmol/L, pH 2.5) as BGE, followed by UV detection at 200 nm. Serum with methylimidazole added as internal standard was deproteinized with acetonitrile and the supernatant, after dilution with water was injected at pressure mode. Creatinine and methylimidazole were baseline-resolved in 6.5 min. Linearity in the 0–880 mmol/L range gave an r2 0.998, recovery was 102 6 2.8% (n = 6). Enzymatic breakdown with creatininase confirmed that serum does not interfere. The within-day and betweendays coefficient of variation (CV) were 2.16 and 2.7%, respectively. The accuracy, determined for lyophilized samples by isotope dilution gas chromatography-mass spectrometry was 6 2.0%. The results were compared with HPLC for 32 lyophilized samples and on 27 serum pools. Capillary electrophoresis, rapid and inexpensive, seems a promising alternative to high-performance liquid chromatography (HPLC) for creatinine determination in human serum.

Creatinine determination in serum by capillary electrophoresis / R. Paroni, I. Fermo, G. Cighetti, C.A. Ferrero, A. Carobene, F. Ceriotti. - In: ELECTROPHORESIS. - ISSN 0173-0835. - 25:3(2004), pp. 463-468.

Creatinine determination in serum by capillary electrophoresis

R. Paroni
Primo
;
G. Cighetti;
2004

Abstract

Creatinine in human serum was separated in a fused-silica capillary with H3PO4 (75 mmol/L, pH 2.5) as BGE, followed by UV detection at 200 nm. Serum with methylimidazole added as internal standard was deproteinized with acetonitrile and the supernatant, after dilution with water was injected at pressure mode. Creatinine and methylimidazole were baseline-resolved in 6.5 min. Linearity in the 0–880 mmol/L range gave an r2 0.998, recovery was 102 6 2.8% (n = 6). Enzymatic breakdown with creatininase confirmed that serum does not interfere. The within-day and betweendays coefficient of variation (CV) were 2.16 and 2.7%, respectively. The accuracy, determined for lyophilized samples by isotope dilution gas chromatography-mass spectrometry was 6 2.0%. The results were compared with HPLC for 32 lyophilized samples and on 27 serum pools. Capillary electrophoresis, rapid and inexpensive, seems a promising alternative to high-performance liquid chromatography (HPLC) for creatinine determination in human serum.
Capillary electrophoresis; Creatinine; High-performance liquid chromatography; Serum
Settore BIO/10 - Biochimica
2004
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/7500
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 23
social impact