A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation.

Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not? / G. Sirico, A. Montisci, F. Secchi, M. Mantica. - In: ACTA MYOLOGICA. - ISSN 1128-2460. - 39:1(2020 Mar), pp. 32-35. [10.36185/2532-1900-006]

Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?

F. Secchi
Penultimo
;
2020

Abstract

A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation.
implantable cardioverter defibrillator; myotonic dystrophy type 1; sudden death
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/36 - Diagnostica per Immagini e Radioterapia
mar-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
am-2020-01-32.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 183.92 kB
Formato Adobe PDF
183.92 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/747059
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact