It is generally accepted that maxilla has a less bone quality than mandible and this fact makes implant rehabilitation more complex. Recently a new type of spiral implants has been introduced in the global market. Since few reports are available a retrospective study was performed. A total of 48 two-piece spiral implants were inserted, 21in female and 27 in males. The median age was 58 ± 8. Implants replaced 10 incisors, 9 cuspids, 25 premolars and 4 molars. Implant' length was 10 mm, 11.5 mm and 13 mm in 13, 24, and 11 cases, respectively. Implant diameter was 3.3 mm, 3.75 mm and 4.2 mm in 25, 17 and 6 cases, respectively. One implant was lost, survival rate (SVR) = 97.91%. Then peri-implant bone resorption was used to investigate success rate (SCR). The mean bone resorption was 0.3 mm after an average period of 1 year follow up. In conclusion the implants studied are reliable devices for oral rehabilitation with a very high SCR and SVR.

Retrospective study on forty-eight fixtures inserted in upper jaw / G. Beltramini, C. Baserga, F. Cullati, A. Piva, V. Candotto. - In: JOURNAL OF BIOLOGICAL REGULATORS & HOMEOSTATIC AGENTS. - ISSN 0393-974X. - 34:1 Suppl. 2(2020 Feb), pp. 25-29.

Retrospective study on forty-eight fixtures inserted in upper jaw

G. Beltramini
Primo
;
C. Baserga
Secondo
;
V. Candotto
Ultimo
2020

Abstract

It is generally accepted that maxilla has a less bone quality than mandible and this fact makes implant rehabilitation more complex. Recently a new type of spiral implants has been introduced in the global market. Since few reports are available a retrospective study was performed. A total of 48 two-piece spiral implants were inserted, 21in female and 27 in males. The median age was 58 ± 8. Implants replaced 10 incisors, 9 cuspids, 25 premolars and 4 molars. Implant' length was 10 mm, 11.5 mm and 13 mm in 13, 24, and 11 cases, respectively. Implant diameter was 3.3 mm, 3.75 mm and 4.2 mm in 25, 17 and 6 cases, respectively. One implant was lost, survival rate (SVR) = 97.91%. Then peri-implant bone resorption was used to investigate success rate (SCR). The mean bone resorption was 0.3 mm after an average period of 1 year follow up. In conclusion the implants studied are reliable devices for oral rehabilitation with a very high SCR and SVR.
bone; fixture; implant; loading; spiral
Settore MED/29 - Chirurgia Maxillofacciale
feb-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
JBRHA34-1(s2).pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 559.99 kB
Formato Adobe PDF
559.99 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/741180
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact