The coupling and latency between heart period (HP) and systolic arterial pressure (SAP) variability can be investigated along the two arms of the HP-SAP closed loop, namely along the baroreflex feedback from SAP to HP, and along the feedforward pathway from HP to SAP. This study investigates the HP-SAP closed loop variability interactions through cross-correlation function (CCF). Coupling strength and delay between HP and SAP variability series were monitored in 13 subjects prone to develop orthostatic syncope (SYNC, 28±9 yrs, 5 males) and in 13 subjects with no history of postural syncope (noSYNC, age: 27±8 yrs, 5 males). Analysis was carried out at rest in supine position (REST) and during head-up tilt (TILT) at 60 degrees. The null hypothesis of HP-SAP uncoupling was tested through a surrogate analysis associating the HP series of a subject with a SAP sequence of a different one. Results showed that during TILT the coupling strength increased along the baroreflex and latency augmented along the mechanical feedforward pathway exclusively in noSYNC subjects. Finally, closed loop HP-SAP interactions were detected in about one third of subjects and the situation of full uncoupling was rarely found. CCF analysis was found to be a straightforward and easily applicable method to investigate HP-SAP control deserving a direct comparison with more sophisticated signal processing tools assessing causality.

Strength and latency of the HP-SAP closed loop variability interactions in subjects prone to develop postural syncope / V. Bari, B. Cairo, E. Vaini, B. De Maria, D. Tonon, G. Rossato, L. Faes, A. Porta (IEEE ENGINEERING IN MEDICINE AND BIOLOGY ... ANNUAL CONFERENCE PROCEEDINGS). - In: 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)[s.l] : IEEE Press, 2019. - ISBN 9781538613115. - pp. 2003-2006 (( Intervento presentato al 41. convegno Annual International Conference of the IEEE EMBS tenutosi a Berlin nel 2019 [10.1109/EMBC.2019.8856288].

Strength and latency of the HP-SAP closed loop variability interactions in subjects prone to develop postural syncope

V. Bari;B. Cairo;A. Porta
Ultimo
2019

Abstract

The coupling and latency between heart period (HP) and systolic arterial pressure (SAP) variability can be investigated along the two arms of the HP-SAP closed loop, namely along the baroreflex feedback from SAP to HP, and along the feedforward pathway from HP to SAP. This study investigates the HP-SAP closed loop variability interactions through cross-correlation function (CCF). Coupling strength and delay between HP and SAP variability series were monitored in 13 subjects prone to develop orthostatic syncope (SYNC, 28±9 yrs, 5 males) and in 13 subjects with no history of postural syncope (noSYNC, age: 27±8 yrs, 5 males). Analysis was carried out at rest in supine position (REST) and during head-up tilt (TILT) at 60 degrees. The null hypothesis of HP-SAP uncoupling was tested through a surrogate analysis associating the HP series of a subject with a SAP sequence of a different one. Results showed that during TILT the coupling strength increased along the baroreflex and latency augmented along the mechanical feedforward pathway exclusively in noSYNC subjects. Finally, closed loop HP-SAP interactions were detected in about one third of subjects and the situation of full uncoupling was rarely found. CCF analysis was found to be a straightforward and easily applicable method to investigate HP-SAP control deserving a direct comparison with more sophisticated signal processing tools assessing causality.
No
English
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
Intervento a convegno
Esperti anonimi
Ricerca applicata
Pubblicazione scientifica
2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
IEEE Press
2019
2003
2006
4
9781538613115
Volume a diffusione internazionale
Annual International Conference of the IEEE EMBS
Berlin
2019
41
Convegno internazionale
Intervento inviato
manual
Aderisco
V. Bari, B. Cairo, E. Vaini, B. De Maria, D. Tonon, G. Rossato, L. Faes, A. Porta
Book Part (author)
reserved
273
Strength and latency of the HP-SAP closed loop variability interactions in subjects prone to develop postural syncope / V. Bari, B. Cairo, E. Vaini, B. De Maria, D. Tonon, G. Rossato, L. Faes, A. Porta (IEEE ENGINEERING IN MEDICINE AND BIOLOGY ... ANNUAL CONFERENCE PROCEEDINGS). - In: 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)[s.l] : IEEE Press, 2019. - ISBN 9781538613115. - pp. 2003-2006 (( Intervento presentato al 41. convegno Annual International Conference of the IEEE EMBS tenutosi a Berlin nel 2019 [10.1109/EMBC.2019.8856288].
info:eu-repo/semantics/bookPart
8
Prodotti della ricerca::03 - Contributo in volume
File in questo prodotto:
File Dimensione Formato  
VBari_EMBC_2019.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 751.35 kB
Formato Adobe PDF
751.35 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/735897
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
  • OpenAlex ND
social impact