We trained a deep neural network for the three-dimensional estimation of the direction of the three anatomical axes (cranio-caudal, anteroposterior and laterolateral) of individual vertebrae from a single sagittal radiographic image acquired from an approximately lateral direction with large deviations from a perfect alignment up to 60 degrees. To this aim, we exploited computed tomography (CT), which can be used to create simulated radiographic projections with different orientations, for the creation of large training and validation datasets. In a set of 21 CT stacks, the location of 5 landmark points was manually determined for L2, L3 and L4, for a total of 63 vertebrae. For each vertebra, 200 simulated projections approximately aligned with sagittal plane but including random perturbations of the projection direction were built, resulting in 12,600 simulated radiographs with the corresponding local directions of the anatomical axes. These data were integrated by 1765 lateral images of vertebrae acquired with a biplanar radiographic imaging system, for which the orientation was calculated by means of three-dimensional reconstruction. The whole dataset was used to train a deep neural network, ResNet-101, customized for the estimation of the three-dimensional components of the axes. The accuracy of the network was qualitatively and quantitatively tested on a large group of simulated radiographic images as well as real lateral images acquired with a biplanar radiographic system for which the direction of the axes was known. Errors were lower than 3 degrees in 76% of the evaluations conducted on the simulated images, and in 86% for the real radiographs. The novel method will be useful to extract three-dimensional information from planar images even in clinical cases in which vertebrae are markedly rotated due to spinal deformities or to an imprecise alignment of the patient with respect to the detector.

Estimating the three-dimensional vertebral orientation from a planar radiograph: Is it feasible? / F. Galbusera, F. Niemeyer, T. Bassani, L.M. Sconfienza, H.-. Wilke. - In: JOURNAL OF BIOMECHANICS. - ISSN 0021-9290. - 102(2020 Mar 26). ((Intervento presentato al 3. convegno International Workshop on Spinal Loading and Deformation : July, 4th - 6th tenutosi a Berlin nel 2019.

Estimating the three-dimensional vertebral orientation from a planar radiograph: Is it feasible?

T. Bassani;L.M. Sconfienza
Penultimo
;
2020

Abstract

We trained a deep neural network for the three-dimensional estimation of the direction of the three anatomical axes (cranio-caudal, anteroposterior and laterolateral) of individual vertebrae from a single sagittal radiographic image acquired from an approximately lateral direction with large deviations from a perfect alignment up to 60 degrees. To this aim, we exploited computed tomography (CT), which can be used to create simulated radiographic projections with different orientations, for the creation of large training and validation datasets. In a set of 21 CT stacks, the location of 5 landmark points was manually determined for L2, L3 and L4, for a total of 63 vertebrae. For each vertebra, 200 simulated projections approximately aligned with sagittal plane but including random perturbations of the projection direction were built, resulting in 12,600 simulated radiographs with the corresponding local directions of the anatomical axes. These data were integrated by 1765 lateral images of vertebrae acquired with a biplanar radiographic imaging system, for which the orientation was calculated by means of three-dimensional reconstruction. The whole dataset was used to train a deep neural network, ResNet-101, customized for the estimation of the three-dimensional components of the axes. The accuracy of the network was qualitatively and quantitatively tested on a large group of simulated radiographic images as well as real lateral images acquired with a biplanar radiographic system for which the direction of the axes was known. Errors were lower than 3 degrees in 76% of the evaluations conducted on the simulated images, and in 86% for the real radiographs. The novel method will be useful to extract three-dimensional information from planar images even in clinical cases in which vertebrae are markedly rotated due to spinal deformities or to an imprecise alignment of the patient with respect to the detector.
Deep learning; EOS; Planar radiograph; Pose; Vertebral orientation
Settore MED/36 - Diagnostica per Immagini e Radioterapia
26-mar-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0021929019305408-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 4.05 MB
Formato Adobe PDF
4.05 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/733381
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact