Postmastectomy radiotherapy (PMRT) following immediate breast reconstruction is increasingly adopted in the management of breast cancer patients. We retrospectively evaluate the complication rates of PMRT using VMAT technique to immediate tissue expander-based reconstructions and the possible impact of tissue expander volume on radiotherapy planning. We reviewed the data of patients who underwent immediate expander breast reconstruction and received PMRT with VMAT (50 Gy in 25 fractions) on the reconstructed breast and axillary levels III–IV. Neoadjuvant or adjuvant systemic therapy was administered in most of the patients. Autologous fat grafting was routinely performed at the time of second-stage reconstruction. Between 2015 and 2017, PMRT was delivered to 46 consecutive patients (median age 50 years) with expander reconstruction. Median follow-up was 27 months (range 10–41). Two patients (4.3%) had a reconstruction failure, as expander rupture and infection, following the first- and the second-stage reconstruction, respectively. In most cases expanders were completely inflated before PMRT (65.2%). Median expander volume before PMRT was 425 cm 3 (range 150–700 cm 3 ). The amount of expander inflation did not significantly affect dosimetry, except for skin dose, with a surface receiving more than 30 Gy of 36.6 ± 0.9 cm 2 and 47.0 ± 2.5 cm 2 for a volume expander below or above the median, respectively. However, this variable was not predictor for complications. Disease progression was recorded in 15.2% of patients. PMRT using VMAT technique for breast cancer patients with expander reconstruction is associated with a very low complication rate. The expander volume before PMRT does not significantly compromise radiotherapy dose distribution.
Postmastectomy radiation therapy using VMAT technique for breast cancer patients with expander reconstruction / F. De Rose, A. Fogliata, D. Franceschini, S. Cozzi, C. Iftode, A. Stravato, S. Tomatis, G. Masci, R. Torrisi, A. Testori, C. Tinterri, A.V.E. Lisa, L. Maione, V. Vinci, M. Klinger, A. Santoro, M. Scorsetti. - In: MEDICAL ONCOLOGY. - ISSN 1357-0560. - 36:6(2019 Apr 25), pp. 48.1-48.8. [10.1007/s12032-019-1275-z]
Postmastectomy radiation therapy using VMAT technique for breast cancer patients with expander reconstruction
A.V.E. Lisa;M. Klinger;
2019
Abstract
Postmastectomy radiotherapy (PMRT) following immediate breast reconstruction is increasingly adopted in the management of breast cancer patients. We retrospectively evaluate the complication rates of PMRT using VMAT technique to immediate tissue expander-based reconstructions and the possible impact of tissue expander volume on radiotherapy planning. We reviewed the data of patients who underwent immediate expander breast reconstruction and received PMRT with VMAT (50 Gy in 25 fractions) on the reconstructed breast and axillary levels III–IV. Neoadjuvant or adjuvant systemic therapy was administered in most of the patients. Autologous fat grafting was routinely performed at the time of second-stage reconstruction. Between 2015 and 2017, PMRT was delivered to 46 consecutive patients (median age 50 years) with expander reconstruction. Median follow-up was 27 months (range 10–41). Two patients (4.3%) had a reconstruction failure, as expander rupture and infection, following the first- and the second-stage reconstruction, respectively. In most cases expanders were completely inflated before PMRT (65.2%). Median expander volume before PMRT was 425 cm 3 (range 150–700 cm 3 ). The amount of expander inflation did not significantly affect dosimetry, except for skin dose, with a surface receiving more than 30 Gy of 36.6 ± 0.9 cm 2 and 47.0 ± 2.5 cm 2 for a volume expander below or above the median, respectively. However, this variable was not predictor for complications. Disease progression was recorded in 15.2% of patients. PMRT using VMAT technique for breast cancer patients with expander reconstruction is associated with a very low complication rate. The expander volume before PMRT does not significantly compromise radiotherapy dose distribution.File | Dimensione | Formato | |
---|---|---|---|
VMAT 2019.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
633.26 kB
Formato
Adobe PDF
|
633.26 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.