Background: Flow cytometry (FC) is used increasingly in veterinary medicine for further characterization of hematolymphoid cells. Guidelines for optimizing assay performance and interpretation of results are limited, and concordance of results across laboratories is unknown. Objectives: This study aimed to determine inter-investigator agreement on the interpretation of FC results from split samples analyzed in different laboratories using various protocols, cytometers, and software; and on the interpretation of archived FC standard (FCS) data files contributed by the different investigators. Methods: This was a multicenter observational cross-sectional study. Anticoagulated blood or lymph node aspirate samples from nine client-owned dogs were aliquoted and shipped to participating laboratories. Samples were analyzed with individual laboratory-developed protocols. In addition, FCS files from a set of separate samples from 11 client-owned dogs were analyzed by participating investigators. A person not associated with the study tabulated the results and interpretations. Agreement of interpretations was assessed with Fleiss’ kappa statistic. Results: Prolonged transit times affected sample quality for some laboratories. Overall agreement among investigators regarding the FC sample interpretation was strong (κ = 0.86 ± 0.19, P <.001), and for specific categories, ranged from moderate to perfect. Agreement of the lymphoproliferation or other leukocyte sample category from the analysis of the FCS files was weak (κ = 0.58 ± 0.05, P <.001). Conclusions: Lymphoproliferations were readily identified by FC, but identification of the categories of hematolymphoid neoplasia in fresh samples or archived files was variable. There is a need for a more standardized approach to maximize the enormous potential of FC in veterinary medicine.

Multicenter flow cytometry proficiency testing of canine blood and lymph node samples / K. Meichner, T. Stokol, J. Tarigo, A. Avery, M.J. Burkhard, S. Comazzi, J. Fogle, D.M. Stowe, B. Rutgen, D. Seelig, A. Wasserkrug-Naor, W. Vernau, D. Bienzle. - In: VETERINARY CLINICAL PATHOLOGY. - ISSN 0275-6382. - 49:2(2020 Jun), pp. 249-257.

Multicenter flow cytometry proficiency testing of canine blood and lymph node samples

S. Comazzi;
2020

Abstract

Background: Flow cytometry (FC) is used increasingly in veterinary medicine for further characterization of hematolymphoid cells. Guidelines for optimizing assay performance and interpretation of results are limited, and concordance of results across laboratories is unknown. Objectives: This study aimed to determine inter-investigator agreement on the interpretation of FC results from split samples analyzed in different laboratories using various protocols, cytometers, and software; and on the interpretation of archived FC standard (FCS) data files contributed by the different investigators. Methods: This was a multicenter observational cross-sectional study. Anticoagulated blood or lymph node aspirate samples from nine client-owned dogs were aliquoted and shipped to participating laboratories. Samples were analyzed with individual laboratory-developed protocols. In addition, FCS files from a set of separate samples from 11 client-owned dogs were analyzed by participating investigators. A person not associated with the study tabulated the results and interpretations. Agreement of interpretations was assessed with Fleiss’ kappa statistic. Results: Prolonged transit times affected sample quality for some laboratories. Overall agreement among investigators regarding the FC sample interpretation was strong (κ = 0.86 ± 0.19, P <.001), and for specific categories, ranged from moderate to perfect. Agreement of the lymphoproliferation or other leukocyte sample category from the analysis of the FCS files was weak (κ = 0.58 ± 0.05, P <.001). Conclusions: Lymphoproliferations were readily identified by FC, but identification of the categories of hematolymphoid neoplasia in fresh samples or archived files was variable. There is a need for a more standardized approach to maximize the enormous potential of FC in veterinary medicine.
assay performance; dog; external laboratory quality assessment; immunophenotyping
Settore VET/03 - Patologia Generale e Anatomia Patologica Veterinaria
giu-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
VCP-19-3512-Final-Accepted.pdf

accesso aperto

Tipologia: Pre-print (manoscritto inviato all'editore)
Dimensione 399.09 kB
Formato Adobe PDF
399.09 kB Adobe PDF Visualizza/Apri
vcp.12843.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 956.71 kB
Formato Adobe PDF
956.71 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/730034
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 7
social impact