Double autologous stem cell transplantation is the standard treatment in newly diagnosed multiple myeloma (MM) patients younger than 65 years; therefore, optimization of leukapheresis is crucial. We performed a retrospective analysis of 297 leukaphereses comparing semiautomated (V4.7 in 20% of collections) versus automated (V6.0 in 80%) Caridian (COBE) Spectra versions and analyzing the influence of M-protein on the outcome. Both methods gave comparable collection efficiencies (CE%) (53.4% vs. 55.7% in V6.0 and V4.7, respectively) with similar leukapheresis time and processed volume. Harvest volume was higher in V4.7 (P < 0.0001) with similar contamination of red blood cells (RBCs) (P = 0.77) and platelets (P = 0.09) when compared with V6.0. In patients with higher peripheral white blood cells (WBCs), V6.0 with adjusted harvest volume (<700 mL), achieved similar CD34(+) CE% (P = 0.39) and better enrichment of nucleated cells (P < 0.0,002) but higher RBCs (P < 0.0,001) and platelets contamination (P = 0.001), when compared with a larger cycle volume in patients with lower WBCs. In hard to mobilize patients, CD34(+) CE% was significantly more efficient with V4.7 than V6.0 (P < 0.0,001). CD34(+) CE% was unaffected by serologic M-protein, but platelet CE% was higher in the absence of M-protein (P = 0.0,003), without any reduction in peripheral patients platelets. We, therefore, conclude that in the setting of MM patients with a high WBCs count and/or low percentage of peripheral CD34(+) cells, collections with V4.7 or adjusted cycle volume V6.0 gave comparable result in CD34(+) CE%. RBCs and platelets contamination is higher if low cycle volume is chosen. In hard to mobilize patients, V4.7 is advisable.

Peripheral blood stem cell collection in multiple myeloma : a retrospective analysis of 6 years leukapheresis activity in 109 patients treated at the Istituto Nazionale dei Tumori of Milan. / P.Coluccia, V.Montefusco, S. Tunesi, M. Avella, A. Bompadre, P. Longoni, M. Milanesi, A. De Carli, F. Ravagnani. - In: JOURNAL OF CLINICAL APHERESIS. - ISSN 0733-2459. - 24:4(2009), pp. 134-140.

Peripheral blood stem cell collection in multiple myeloma : a retrospective analysis of 6 years leukapheresis activity in 109 patients treated at the Istituto Nazionale dei Tumori of Milan.

S. Tunesi;A. De Carli
Penultimo
;
2009

Abstract

Double autologous stem cell transplantation is the standard treatment in newly diagnosed multiple myeloma (MM) patients younger than 65 years; therefore, optimization of leukapheresis is crucial. We performed a retrospective analysis of 297 leukaphereses comparing semiautomated (V4.7 in 20% of collections) versus automated (V6.0 in 80%) Caridian (COBE) Spectra versions and analyzing the influence of M-protein on the outcome. Both methods gave comparable collection efficiencies (CE%) (53.4% vs. 55.7% in V6.0 and V4.7, respectively) with similar leukapheresis time and processed volume. Harvest volume was higher in V4.7 (P < 0.0001) with similar contamination of red blood cells (RBCs) (P = 0.77) and platelets (P = 0.09) when compared with V6.0. In patients with higher peripheral white blood cells (WBCs), V6.0 with adjusted harvest volume (<700 mL), achieved similar CD34(+) CE% (P = 0.39) and better enrichment of nucleated cells (P < 0.0,002) but higher RBCs (P < 0.0,001) and platelets contamination (P = 0.001), when compared with a larger cycle volume in patients with lower WBCs. In hard to mobilize patients, CD34(+) CE% was significantly more efficient with V4.7 than V6.0 (P < 0.0,001). CD34(+) CE% was unaffected by serologic M-protein, but platelet CE% was higher in the absence of M-protein (P = 0.0,003), without any reduction in peripheral patients platelets. We, therefore, conclude that in the setting of MM patients with a high WBCs count and/or low percentage of peripheral CD34(+) cells, collections with V4.7 or adjusted cycle volume V6.0 gave comparable result in CD34(+) CE%. RBCs and platelets contamination is higher if low cycle volume is chosen. In hard to mobilize patients, V4.7 is advisable.
Collection efficiency; Multiple myeloma; Peripheral blood stem cell(s)
Settore MED/01 - Statistica Medica
2009
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/72827
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact