BACKGROUND AND PURPOSE: CT Perfusion (CTP) has shown potential for assessing head and neck tumors. Our purposes were to assess the inter- and intraobserver agreement of CTP measurements and to investigate whether the selection of arterial input, ipsilateral versus contralateral to the tumor or left-versus-right external carotid artery (ECA), may affect CTP measurements in patients with squamous cell carcinoma (SCCA) of the upper aerodigestive tract. MATERIALS AND METHODS: Twenty-six patients with SCCA were enrolled in this prospective study and underwent CTP. Data were analyzed by 2 expert readers and by an inexperienced reader for interobserver agreement and by the 2 expert readers for intraobserver agreement assessment, by using the ECA ipsilateral to tumor site as arterial input. All 3 readers repeated their analysis by using the ECA contralateral to tumor site as arterial input. Inter- and intraobserver agreement was assessed by using the Bland-Altman approach; CTP measurements by using ipsilateral-versus-contralateral or left-versus-right ECA were compared by using the Wilcoxon signed rank test. RESULTS: The geometric mean of the ratios (95% limits of agreement) for inter- and intraobserver agreement ranged from 0.96 (0.75-1.23) to 1.00 (0.92-1.10) for blood flow (BF), from 0.88 (0.63-1.21) to 1.00 (0.88-1.14) for blood volume (BV), from 0.96 (0.64-1.44) to 0.98 (0.76-1.27) for mean transit time (MTT), and from 0.85 (0.41-1.76) to 1.14 (0.70-1.86) for permeability surface area product (PS). Significantly higher tumor PS and MTT for 2 readers and lower tumor BF for 1 of 3 readers were observed when the arterial input was placed in the left ECA. CONCLUSIONS: BF, BV, and MTT demonstrated higher inter- and intraobserver agreement than PS. The selection of arterial input, right-versus-left ECA, may determine changes in CTP measurements in patients with SCCA of the upper aerodigestive tract.

Impact of intra- and interobserver variability and of arterial input selection in perfusion CT measurement performed in squamous cell carcinoma of the upper aero-digestive tract / G. Petralia, L. Preda, S. Raimondi, G. D’Andrea, P. Summers, G. Giugliano, F. Chiesa, M. Bellomi. - In: AJNR, AMERICAN JOURNAL OF NEURORADIOLOGY. - ISSN 0195-6108. - 30:6(2009), pp. 1107-1115.

Impact of intra- and interobserver variability and of arterial input selection in perfusion CT measurement performed in squamous cell carcinoma of the upper aero-digestive tract

G. Petralia;M. Bellomi
Ultimo
2009

Abstract

BACKGROUND AND PURPOSE: CT Perfusion (CTP) has shown potential for assessing head and neck tumors. Our purposes were to assess the inter- and intraobserver agreement of CTP measurements and to investigate whether the selection of arterial input, ipsilateral versus contralateral to the tumor or left-versus-right external carotid artery (ECA), may affect CTP measurements in patients with squamous cell carcinoma (SCCA) of the upper aerodigestive tract. MATERIALS AND METHODS: Twenty-six patients with SCCA were enrolled in this prospective study and underwent CTP. Data were analyzed by 2 expert readers and by an inexperienced reader for interobserver agreement and by the 2 expert readers for intraobserver agreement assessment, by using the ECA ipsilateral to tumor site as arterial input. All 3 readers repeated their analysis by using the ECA contralateral to tumor site as arterial input. Inter- and intraobserver agreement was assessed by using the Bland-Altman approach; CTP measurements by using ipsilateral-versus-contralateral or left-versus-right ECA were compared by using the Wilcoxon signed rank test. RESULTS: The geometric mean of the ratios (95% limits of agreement) for inter- and intraobserver agreement ranged from 0.96 (0.75-1.23) to 1.00 (0.92-1.10) for blood flow (BF), from 0.88 (0.63-1.21) to 1.00 (0.88-1.14) for blood volume (BV), from 0.96 (0.64-1.44) to 0.98 (0.76-1.27) for mean transit time (MTT), and from 0.85 (0.41-1.76) to 1.14 (0.70-1.86) for permeability surface area product (PS). Significantly higher tumor PS and MTT for 2 readers and lower tumor BF for 1 of 3 readers were observed when the arterial input was placed in the left ECA. CONCLUSIONS: BF, BV, and MTT demonstrated higher inter- and intraobserver agreement than PS. The selection of arterial input, right-versus-left ECA, may determine changes in CTP measurements in patients with SCCA of the upper aerodigestive tract.
Settore MED/36 - Diagnostica per Immagini e Radioterapia
2009
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/72589
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 20
social impact