Objectives: To evaluate image quality, coronary evaluability and radiation exposure of coronary CT angiography (CCTA) performed with whole-heart coverage cardiac-CT in patients with atrial fibrillation (AF). Materials and methods: We prospectively enrolled 164 patients with AF who underwent a clinically indicated CCTA with a 16-cm z-axis coverage scanner. In all patients CCTA was performed using prospective ECG-triggering with targeted RR interval. We evaluated image quality, coronary evaluability and effective dose (ED). Patients were divided in two subgroups based on heart rate (HR) during imaging. Group 1: 64 patients with low HR (OpenSPiltSPi75 bpm), group 2: 100 patients with high HR (≥75 bpm). Written informed consent was obtained from all patients and the institutional ethics committee approved the study protocol. Results: In a segment-based analysis, coronary evaluability was 98.4 % (2,577/2,620 segments) in the whole population, without significant differences between groups (1,013/1,024 (98.9 %) and 1,565/1,596 (98.1 %), for groups 1 and 2, respectively, p=0.15). Mean ED was similar in both groups (3.8±1.9 mSv and 3.9±2.1 mSv in groups 1 and 2, respectively, p=0.75) Conclusions: The whole-heart-coverage scanner could evaluate coronary arteries with high image quality and without increase in radiation exposure in AF patients, even in the high HR group. Key points: • Last-generation CT scanner improves coronary artery assessment in AF patients. • The new CT scanner enables low radiation exposure in AF patients. • Diagnostic ICA maybe avoided in AF patients with suspected CAD. • Whole-heart coverage CT scanner enables low radiation exposure in AF patients.

Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation / D. Andreini, G. Pontone, S. Mushtaq, M.E. Mancini, E. Conte, M. Guglielmo, V. Volpato, A. Annoni, A. Baggiano, A. Formenti, V. Ditali, M. Perchinunno, C. Fiorentini, A.L. Bartorelli, M. Pepi. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 28:4(2018 Apr), pp. 1383-1392. [10.1007/s00330-017-5131-2]

Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation

D. Andreini
;
G. Pontone;S. Mushtaq;E. Conte;V. Volpato;A. Baggiano;A. Formenti;C. Fiorentini;A.L. Bartorelli;
2018

Abstract

Objectives: To evaluate image quality, coronary evaluability and radiation exposure of coronary CT angiography (CCTA) performed with whole-heart coverage cardiac-CT in patients with atrial fibrillation (AF). Materials and methods: We prospectively enrolled 164 patients with AF who underwent a clinically indicated CCTA with a 16-cm z-axis coverage scanner. In all patients CCTA was performed using prospective ECG-triggering with targeted RR interval. We evaluated image quality, coronary evaluability and effective dose (ED). Patients were divided in two subgroups based on heart rate (HR) during imaging. Group 1: 64 patients with low HR (OpenSPiltSPi75 bpm), group 2: 100 patients with high HR (≥75 bpm). Written informed consent was obtained from all patients and the institutional ethics committee approved the study protocol. Results: In a segment-based analysis, coronary evaluability was 98.4 % (2,577/2,620 segments) in the whole population, without significant differences between groups (1,013/1,024 (98.9 %) and 1,565/1,596 (98.1 %), for groups 1 and 2, respectively, p=0.15). Mean ED was similar in both groups (3.8±1.9 mSv and 3.9±2.1 mSv in groups 1 and 2, respectively, p=0.75) Conclusions: The whole-heart-coverage scanner could evaluate coronary arteries with high image quality and without increase in radiation exposure in AF patients, even in the high HR group. Key points: • Last-generation CT scanner improves coronary artery assessment in AF patients. • The new CT scanner enables low radiation exposure in AF patients. • Diagnostic ICA maybe avoided in AF patients with suspected CAD. • Whole-heart coverage CT scanner enables low radiation exposure in AF patients.
No
English
Atrial fibrillation; Coronary CT angiography; Coronary evaluability; Image quality; Radiation dose; Radiology, Nuclear Medicine and Imaging
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Articolo
Esperti anonimi
Pubblicazione scientifica
apr-2018
Springer
28
4
1383
1392
10
Pubblicato
Periodico con rilevanza internazionale
Aderisco
info:eu-repo/semantics/article
Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation / D. Andreini, G. Pontone, S. Mushtaq, M.E. Mancini, E. Conte, M. Guglielmo, V. Volpato, A. Annoni, A. Baggiano, A. Formenti, V. Ditali, M. Perchinunno, C. Fiorentini, A.L. Bartorelli, M. Pepi. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 28:4(2018 Apr), pp. 1383-1392. [10.1007/s00330-017-5131-2]
reserved
Prodotti della ricerca::01 - Articolo su periodico
15
262
Article (author)
si
D. Andreini, G. Pontone, S. Mushtaq, M.E. Mancini, E. Conte, M. Guglielmo, V. Volpato, A. Annoni, A. Baggiano, A. Formenti, V. Ditali, M. Perchinunno,...espandi
File in questo prodotto:
File Dimensione Formato  
Image.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 2.84 MB
Formato Adobe PDF
2.84 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/724484
Citazioni
  • ???jsp.display-item.citation.pmc??? 27
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 58
  • OpenAlex ND
social impact