Selective embolization is the treatment of choice for traumatic renal pseudoaneurysm. The use of ethylene vinyl alcohol copolymer (EVOH) was recently described as an embolic agent in peripheral lesions. The aim of a good embolic agent is to: achieve rapid and effective embolization; reach and fill distal vasculature targeted for embolization; be easy to prepare and use. Moreover, it should be highly radiopaque, controllable during administration, biocompatible and cost-effective. EVOH is a non-adhesive embolic agent and its efficacy is independent from the coagulant status. The risk of non-targeted embolization should be reduced by the good radio-opacity of the embolic material that is injected under continuous fluoroscopy. Nevertheless, symptomatic EVOH migration was described. We report a unique case of embolization of a renal pseudoaneurysm and migration of EVOH in the urinary tract. Retrograde trans-urethral removal of the migrated embolic agent was successfully performed. Our case report indicates that EVOH may not be appropriate when a fistula with renal calyx is suspected, even if its migration in the urinary tract may be managed.

Migration of ethylene vinyl alcohol co-polymer in the urinary tract successfully managed / A.M. Ierardi, F. Pesapane, A. Arrichiello, F. Fontana, F. Piacentino, G. Carrafiello. - In: MEDICINA. - ISSN 1010-660X. - 55:6(2019 Jun), pp. 234.1-234.8. [10.3390/medicina55060234]

Migration of ethylene vinyl alcohol co-polymer in the urinary tract successfully managed

F. Pesapane
;
A. Arrichiello;F. Fontana;G. Carrafiello
2019

Abstract

Selective embolization is the treatment of choice for traumatic renal pseudoaneurysm. The use of ethylene vinyl alcohol copolymer (EVOH) was recently described as an embolic agent in peripheral lesions. The aim of a good embolic agent is to: achieve rapid and effective embolization; reach and fill distal vasculature targeted for embolization; be easy to prepare and use. Moreover, it should be highly radiopaque, controllable during administration, biocompatible and cost-effective. EVOH is a non-adhesive embolic agent and its efficacy is independent from the coagulant status. The risk of non-targeted embolization should be reduced by the good radio-opacity of the embolic material that is injected under continuous fluoroscopy. Nevertheless, symptomatic EVOH migration was described. We report a unique case of embolization of a renal pseudoaneurysm and migration of EVOH in the urinary tract. Retrograde trans-urethral removal of the migrated embolic agent was successfully performed. Our case report indicates that EVOH may not be appropriate when a fistula with renal calyx is suspected, even if its migration in the urinary tract may be managed.
Complication; EVOH; Interventional radiology; Migration; Onyx; Pseudoaneurysm; Aged; Aneurysm, False; Embolization, Therapeutic; Humans; Male; Polyvinyls; Tomography, X-Ray Computed; Urinary Tract
Settore MED/36 - Diagnostica per Immagini e Radioterapia
giu-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
medicina-55-00234-v2.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 2.69 MB
Formato Adobe PDF
2.69 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/723868
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact