To test true-fast imaging with steady-state precession (true-FISP) added to gadolinium-based MR angiography (Gd-MRA) for imaging abdominal aorta and major abdominal vessels, 35 consecutive patients (age 67 ± 11 years) with known or suspected abdominal and/or peripheral vascular disease were studied with sagittal and axial 2D true-FISP during free breathing and coronal 3D fast low-angle shot (FLASH) Gd-MRA (breath-holding, 0.2 mmol/kg of Gd-DOTA at 2 ml/s). We evaluated: suprarenal aorta, celiac trunk, superior mesenteric artery, right renal artery, left renal artery, infrarenal aorta, inferior mesenteric artery, aortic bifurcation/common iliac arteries, lumbar arteries and aortic atheromasia. The possible presence of accessory renal arteries, collateral vasculature and vascular prosthesis/stent was evaluated. A quality four-point score was assigned to each item on both sequences, from 0 (not visible) to 3 (good-to-excellent image quality) and Wilcoxon test was used. Main diagnoses resulted: normal or atheromasic aorta (n = 25); aortic aneurysm (n = 2); patent aorto-iliac surgical prosthesis (n = 2); patent vascular iliac stent (n = 2); aneurysm of iliac artery (n = 1); patent aortic endovascular prosthesis (n = 1); patent aorto-femural bypass (n = 1) and aorto-iliac surgical prosthesis endoleak (n = 1). We also found three patients with accessory renal arteries, two with collateral circulation, and three with surgical aorto-iliac prosthesis. The score of true-FISP (25.9 ± 4.1, median 27) was significantly higher (p = 0.003) than that of Gd-MRA (23.9 ± 3.6, median 24). True-FISP was superior for visualizing inferior mesenteric artery (score 2.5 ± 1.1 vs. 1.0 ± 1.4; p < 0.001) and atheromasic plaques (2.5 ± 1.1 vs. 1.2 ± 1.1; p < 0.001). One collateral vasculature was demonstrated only with Gd-MRA. Summarizing, true-FISP is a power and fast non-breath-hold sequence to be added to Gd-MRA, obtaining an information increase.

The value of true-FISP sequence added to conventional gadolinium-enhanced MRA of abdominal aorta and its major branches / A. Iozzelli, G. D'Orta, A. Aliprandi, F. Secchi, G. Di Leo, F. Sardanelli. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - 72:3(2009), pp. 489-493.

The value of true-FISP sequence added to conventional gadolinium-enhanced MRA of abdominal aorta and its major branches

F. Secchi;F. Sardanelli
Ultimo
2009

Abstract

To test true-fast imaging with steady-state precession (true-FISP) added to gadolinium-based MR angiography (Gd-MRA) for imaging abdominal aorta and major abdominal vessels, 35 consecutive patients (age 67 ± 11 years) with known or suspected abdominal and/or peripheral vascular disease were studied with sagittal and axial 2D true-FISP during free breathing and coronal 3D fast low-angle shot (FLASH) Gd-MRA (breath-holding, 0.2 mmol/kg of Gd-DOTA at 2 ml/s). We evaluated: suprarenal aorta, celiac trunk, superior mesenteric artery, right renal artery, left renal artery, infrarenal aorta, inferior mesenteric artery, aortic bifurcation/common iliac arteries, lumbar arteries and aortic atheromasia. The possible presence of accessory renal arteries, collateral vasculature and vascular prosthesis/stent was evaluated. A quality four-point score was assigned to each item on both sequences, from 0 (not visible) to 3 (good-to-excellent image quality) and Wilcoxon test was used. Main diagnoses resulted: normal or atheromasic aorta (n = 25); aortic aneurysm (n = 2); patent aorto-iliac surgical prosthesis (n = 2); patent vascular iliac stent (n = 2); aneurysm of iliac artery (n = 1); patent aortic endovascular prosthesis (n = 1); patent aorto-femural bypass (n = 1) and aorto-iliac surgical prosthesis endoleak (n = 1). We also found three patients with accessory renal arteries, two with collateral circulation, and three with surgical aorto-iliac prosthesis. The score of true-FISP (25.9 ± 4.1, median 27) was significantly higher (p = 0.003) than that of Gd-MRA (23.9 ± 3.6, median 24). True-FISP was superior for visualizing inferior mesenteric artery (score 2.5 ± 1.1 vs. 1.0 ± 1.4; p < 0.001) and atheromasic plaques (2.5 ± 1.1 vs. 1.2 ± 1.1; p < 0.001). One collateral vasculature was demonstrated only with Gd-MRA. Summarizing, true-FISP is a power and fast non-breath-hold sequence to be added to Gd-MRA, obtaining an information increase.
Settore MED/36 - Diagnostica per Immagini e Radioterapia
2009
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/71258
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 16
social impact