Virtual planning in orthognathic surgery has nowadays become a clinical reality and has introduced important advantages in terms of accuracy and planning duration when compared to conventional surgical planning. One of the main concerns regarding virtual planning is the method that is used to transfer the virtual surgical plan into the operation theater. With the many transferring methods proposed, the evidence is confusion regarding the accuracy of each of these methods for reliably transferring the virtual plan. Furthermore, the accuracy analysis itself, has been performed with numerous techniques and not all of them are capable of producing reliable results on the accuracy of different transferring methods. The purpose of this study is to compare two transferring methods, the CAD/CAM intermediate splint and the customized surgical guide with fixation plates, by means of a voxel-based landmark free accuracy analysis.
ACCURACY OF SPLINT VS SPLINTLESS TECHNIQUE FOR VIRTUALLY PLANNED ORTHOGNATHIC SURGERY: A VOXEL BASED THREE-DIMENSIONAL ANALYSIS / L. Karanxha ; tutor: M. DEL FABBRI ; co-tutor: A. GIANNI', W. MOON. Università degli Studi di Milano, 2019 Dec 16. 32. ciclo, Anno Accademico 2019. [10.13130/karanxha-lorena_phd2019-12-16].
ACCURACY OF SPLINT VS SPLINTLESS TECHNIQUE FOR VIRTUALLY PLANNED ORTHOGNATHIC SURGERY: A VOXEL BASED THREE-DIMENSIONAL ANALYSIS
L. Karanxha
2019
Abstract
Virtual planning in orthognathic surgery has nowadays become a clinical reality and has introduced important advantages in terms of accuracy and planning duration when compared to conventional surgical planning. One of the main concerns regarding virtual planning is the method that is used to transfer the virtual surgical plan into the operation theater. With the many transferring methods proposed, the evidence is confusion regarding the accuracy of each of these methods for reliably transferring the virtual plan. Furthermore, the accuracy analysis itself, has been performed with numerous techniques and not all of them are capable of producing reliable results on the accuracy of different transferring methods. The purpose of this study is to compare two transferring methods, the CAD/CAM intermediate splint and the customized surgical guide with fixation plates, by means of a voxel-based landmark free accuracy analysis.File | Dimensione | Formato | |
---|---|---|---|
phd_unimi_R11662.pdf
Open Access dal 14/07/2020
Descrizione: MATERIALE COMPLETO STUDIO CLINICO
Tipologia:
Tesi di dottorato completa
Dimensione
6.32 MB
Formato
Adobe PDF
|
6.32 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.