Background: Lacking assay standardization, different myoglobin methods may produce results that differ significantly. Methods: A multicenter study was carried out to compare the analytical performance of five commercially available assays for myoglobin measurement. Linearity, imprecision, interferences, and method comparison were studied according to NCCLS guidelines, whereas reference values were determined following IFCC recommendations; Results: The BNA and Opus showed relatively high imprecision (all but one total CV >7.4%). Other assays showed lower CVs, but they varied among laboratories, particularly at a normal myoglobin concentration (Access, 6.0-11%; Hitachi, 3.8-5.8%; Stratus, 3.4-6.5%). Results were lower in anticoagulated samples on the Access, in heparin and citrate samples on the Stratus, and in citrate samples on the BNA and Opus, and increased in heparin and EDTA samples on the Hitachi. Use of separator gel produced results significantly lower (P <0.001) on the Hitachi and higher (P = 0.016) on the Opus. Bilirubin, turbidity, and hemoglobin had no effect on evaluated methods, but rheumatoid factor affected the Access. In method comparisons, high correlation coefficients (greater than or equal to 0.98) were obtained. The Stratus gave higher results; however, the Access and BNA gave the lowest. The following upper reference limits (mu g/L) for men and women, respectively, were obtained: Access, 70 and 52; BNA, 51 and 49; Hitachi, 67 and 58; Opus, 80 and 50; and Stratus, 86 and 63. Conclusion: The possibility of high imprecision and marked disagreement among commercial myoglobin assays should be carefully considered in clinical practice.

Multicenter evaluation of five assays for myoglobin determination / M. Zaninotto, F. Pagani, S. Altinier, P. Amboni, R. Bonora, A. Dolci, P. Pergolini, A. Vernocchi, M. Plebani, M. Panteghini. - In: CLINICAL CHEMISTRY. - ISSN 0009-9147. - 46:10(2000), pp. 1631-1637. (Intervento presentato al convegno Annual Meeting of the American-Association-of-Clinical-Chemistry tenutosi a Chicago nel 1998).

Multicenter evaluation of five assays for myoglobin determination

A. Dolci;M. Panteghini
2000

Abstract

Background: Lacking assay standardization, different myoglobin methods may produce results that differ significantly. Methods: A multicenter study was carried out to compare the analytical performance of five commercially available assays for myoglobin measurement. Linearity, imprecision, interferences, and method comparison were studied according to NCCLS guidelines, whereas reference values were determined following IFCC recommendations; Results: The BNA and Opus showed relatively high imprecision (all but one total CV >7.4%). Other assays showed lower CVs, but they varied among laboratories, particularly at a normal myoglobin concentration (Access, 6.0-11%; Hitachi, 3.8-5.8%; Stratus, 3.4-6.5%). Results were lower in anticoagulated samples on the Access, in heparin and citrate samples on the Stratus, and in citrate samples on the BNA and Opus, and increased in heparin and EDTA samples on the Hitachi. Use of separator gel produced results significantly lower (P <0.001) on the Hitachi and higher (P = 0.016) on the Opus. Bilirubin, turbidity, and hemoglobin had no effect on evaluated methods, but rheumatoid factor affected the Access. In method comparisons, high correlation coefficients (greater than or equal to 0.98) were obtained. The Stratus gave higher results; however, the Access and BNA gave the lowest. The following upper reference limits (mu g/L) for men and women, respectively, were obtained: Access, 70 and 52; BNA, 51 and 49; Hitachi, 67 and 58; Opus, 80 and 50; and Stratus, 86 and 63. Conclusion: The possibility of high imprecision and marked disagreement among commercial myoglobin assays should be carefully considered in clinical practice.
Approved recommendation 1987; myocardial-infarction; reference values; troponin-I; markers; strategies; proposalsa; serum
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2000
Article (author)
File in questo prodotto:
File Dimensione Formato  
2000 Clin Chem - Myoglobin evaluation.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 223.83 kB
Formato Adobe PDF
223.83 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/702652
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact