The imaging performances of multiphoton excitation and confocal laser scanning microscopy are herby considered: in typical experimental imaging conditions, a small finite amount of photon reaches the detector giving shot-noise fluctuations which affects the signal acquired. A significant detriment in the high frequencies transmission capability is obtained. In order to partially recover the high frequencies information lost, the insertion of a pupil plane filter in the microscope illumination light pathway on the objective lens is proposed. We demonstrate high-frequency and resolution enhancement in the case of linear and non linear fluorescence microscope approach under shot-noise condition.

Annular pupil filter under shot-noise condition for linear and non linear microscopy / E. Ronzitti, G. Vicidomini, V. Caorsi, A. Diaspro. - In: OPTICS EXPRESS. - ISSN 1094-4087. - 17:8(2009 Apr 13), pp. 6867-6880. [10.1364/OE.17.006867]

Annular pupil filter under shot-noise condition for linear and non linear microscopy

E. Ronzitti
Primo
;
2009

Abstract

The imaging performances of multiphoton excitation and confocal laser scanning microscopy are herby considered: in typical experimental imaging conditions, a small finite amount of photon reaches the detector giving shot-noise fluctuations which affects the signal acquired. A significant detriment in the high frequencies transmission capability is obtained. In order to partially recover the high frequencies information lost, the insertion of a pupil plane filter in the microscope illumination light pathway on the objective lens is proposed. We demonstrate high-frequency and resolution enhancement in the case of linear and non linear fluorescence microscope approach under shot-noise condition.
English
Settore FIS/03 - Fisica della Materia
Articolo
Sì, ma tipo non specificato
13-apr-2009
Optical Society of America
17
8
6867
6880
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Annular pupil filter under shot-noise condition for linear and non linear microscopy / E. Ronzitti, G. Vicidomini, V. Caorsi, A. Diaspro. - In: OPTICS EXPRESS. - ISSN 1094-4087. - 17:8(2009 Apr 13), pp. 6867-6880. [10.1364/OE.17.006867]
none
Prodotti della ricerca::01 - Articolo su periodico
4
262
Article (author)
Periodico con Impact Factor
E. Ronzitti, G. Vicidomini, V. Caorsi, A. Diaspro
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/69883
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
  • OpenAlex ND
social impact