Purpose To assess the feasibility and reproducibility of T2 relaxation time measurements of the trapeziometacarpal joint (TM) and triangular fibrocartilage complex (TFCC) on healthy subjects at 1.5 T MR. Materials and methods Thirty-four healthy volunteers underwent an axial oblique multislice multiecho spin-echo sequence of the wrist at 1.5 T, with 10 of them having performed another MR scan on a different 1.5 T scanner. Regions of interest were independently manually drawn by two musculoskeletal radiologists to include the cartilaginous part of the TM and TFCC. Intra-observer, inter-observer and inter-scanner reproducibility of T2 relaxation time measurements was tested using the Bland-Altman method. Results The mean T2 values obtained by the two radiologists were 29.9 +/- 6.5 ms and 30.0 +/- 6.1 ms in the TM and 24.5 +/- 2.3 ms and 24.6 +/- 2.8 ms in the TFCC, respectively. The mean values of the second series of T2 measurements obtained by the senior radiologist were 29.9 +/- 6.5 ms and 30.0 +/- 6.3 ms in the TM and 24.3 +/- 2.9 ms in the TFCC. Inter-observer reproducibility in the TM and in the TFCC was 76% and 82%, respectively. Intra-observer reproducibility in the TM and TFCC was 71% and 76%, respectively. Inter-scanner reproducibility of T2 measurements was 36% in the TM and 85% in the TFCC, respectively. Conclusion The assessment of T2 relaxation time measurements of the cartilage of the TM and the TFCC seems to be feasible and reproducible, although the inter-scanner reproducibility of T2 measurements of the TM is suboptimal. Further studies including patients are warranted to prove the utility of this tool.
T2 mapping of the trapeziometacarpal joint and triangular fibrocartilage complex: a feasibility and reproducibility study at 1.5 T / V. Chianca, D. Albano, R. Cuocolo, C. Messina, S. Gitto, A. Brunetti, L.M. Sconfienza. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - 125:3(2020 Mar), pp. 306-312. [10.1007/s11547-019-01123-8]
T2 mapping of the trapeziometacarpal joint and triangular fibrocartilage complex: a feasibility and reproducibility study at 1.5 T
D. Albano;C. Messina;S. Gitto;L.M. SconfienzaUltimo
2020
Abstract
Purpose To assess the feasibility and reproducibility of T2 relaxation time measurements of the trapeziometacarpal joint (TM) and triangular fibrocartilage complex (TFCC) on healthy subjects at 1.5 T MR. Materials and methods Thirty-four healthy volunteers underwent an axial oblique multislice multiecho spin-echo sequence of the wrist at 1.5 T, with 10 of them having performed another MR scan on a different 1.5 T scanner. Regions of interest were independently manually drawn by two musculoskeletal radiologists to include the cartilaginous part of the TM and TFCC. Intra-observer, inter-observer and inter-scanner reproducibility of T2 relaxation time measurements was tested using the Bland-Altman method. Results The mean T2 values obtained by the two radiologists were 29.9 +/- 6.5 ms and 30.0 +/- 6.1 ms in the TM and 24.5 +/- 2.3 ms and 24.6 +/- 2.8 ms in the TFCC, respectively. The mean values of the second series of T2 measurements obtained by the senior radiologist were 29.9 +/- 6.5 ms and 30.0 +/- 6.3 ms in the TM and 24.3 +/- 2.9 ms in the TFCC. Inter-observer reproducibility in the TM and in the TFCC was 76% and 82%, respectively. Intra-observer reproducibility in the TM and TFCC was 71% and 76%, respectively. Inter-scanner reproducibility of T2 measurements was 36% in the TM and 85% in the TFCC, respectively. Conclusion The assessment of T2 relaxation time measurements of the cartilage of the TM and the TFCC seems to be feasible and reproducible, although the inter-scanner reproducibility of T2 measurements of the TM is suboptimal. Further studies including patients are warranted to prove the utility of this tool.File | Dimensione | Formato | |
---|---|---|---|
10.1007_s11547-019-01123-8.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
1.01 MB
Formato
Adobe PDF
|
1.01 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Chianca2020_Article_T2MappingOfTheTrapeziometacarp.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
944.53 kB
Formato
Adobe PDF
|
944.53 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.