Purpose To assess the feasibility and reproducibility of T2 relaxation time measurements of the trapeziometacarpal joint (TM) and triangular fibrocartilage complex (TFCC) on healthy subjects at 1.5 T MR. Materials and methods Thirty-four healthy volunteers underwent an axial oblique multislice multiecho spin-echo sequence of the wrist at 1.5 T, with 10 of them having performed another MR scan on a different 1.5 T scanner. Regions of interest were independently manually drawn by two musculoskeletal radiologists to include the cartilaginous part of the TM and TFCC. Intra-observer, inter-observer and inter-scanner reproducibility of T2 relaxation time measurements was tested using the Bland-Altman method. Results The mean T2 values obtained by the two radiologists were 29.9 +/- 6.5 ms and 30.0 +/- 6.1 ms in the TM and 24.5 +/- 2.3 ms and 24.6 +/- 2.8 ms in the TFCC, respectively. The mean values of the second series of T2 measurements obtained by the senior radiologist were 29.9 +/- 6.5 ms and 30.0 +/- 6.3 ms in the TM and 24.3 +/- 2.9 ms in the TFCC. Inter-observer reproducibility in the TM and in the TFCC was 76% and 82%, respectively. Intra-observer reproducibility in the TM and TFCC was 71% and 76%, respectively. Inter-scanner reproducibility of T2 measurements was 36% in the TM and 85% in the TFCC, respectively. Conclusion The assessment of T2 relaxation time measurements of the cartilage of the TM and the TFCC seems to be feasible and reproducible, although the inter-scanner reproducibility of T2 measurements of the TM is suboptimal. Further studies including patients are warranted to prove the utility of this tool.

T2 mapping of the trapeziometacarpal joint and triangular fibrocartilage complex: a feasibility and reproducibility study at 1.5 T / V. Chianca, D. Albano, R. Cuocolo, C. Messina, S. Gitto, A. Brunetti, L.M. Sconfienza. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - 125:3(2020 Mar), pp. 306-312. [10.1007/s11547-019-01123-8]

T2 mapping of the trapeziometacarpal joint and triangular fibrocartilage complex: a feasibility and reproducibility study at 1.5 T

D. Albano;C. Messina;S. Gitto;L.M. Sconfienza
Ultimo
2020

Abstract

Purpose To assess the feasibility and reproducibility of T2 relaxation time measurements of the trapeziometacarpal joint (TM) and triangular fibrocartilage complex (TFCC) on healthy subjects at 1.5 T MR. Materials and methods Thirty-four healthy volunteers underwent an axial oblique multislice multiecho spin-echo sequence of the wrist at 1.5 T, with 10 of them having performed another MR scan on a different 1.5 T scanner. Regions of interest were independently manually drawn by two musculoskeletal radiologists to include the cartilaginous part of the TM and TFCC. Intra-observer, inter-observer and inter-scanner reproducibility of T2 relaxation time measurements was tested using the Bland-Altman method. Results The mean T2 values obtained by the two radiologists were 29.9 +/- 6.5 ms and 30.0 +/- 6.1 ms in the TM and 24.5 +/- 2.3 ms and 24.6 +/- 2.8 ms in the TFCC, respectively. The mean values of the second series of T2 measurements obtained by the senior radiologist were 29.9 +/- 6.5 ms and 30.0 +/- 6.3 ms in the TM and 24.3 +/- 2.9 ms in the TFCC. Inter-observer reproducibility in the TM and in the TFCC was 76% and 82%, respectively. Intra-observer reproducibility in the TM and TFCC was 71% and 76%, respectively. Inter-scanner reproducibility of T2 measurements was 36% in the TM and 85% in the TFCC, respectively. Conclusion The assessment of T2 relaxation time measurements of the cartilage of the TM and the TFCC seems to be feasible and reproducible, although the inter-scanner reproducibility of T2 measurements of the TM is suboptimal. Further studies including patients are warranted to prove the utility of this tool.
Cartilage; Magnetic resonance imaging; T2 mapping; Trapeziometacarpal joint; Triangular fibrocartilage complex
Settore MED/36 - Diagnostica per Immagini e Radioterapia
mar-2020
20-dic-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
10.1007_s11547-019-01123-8.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.01 MB
Formato Adobe PDF
1.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Chianca2020_Article_T2MappingOfTheTrapeziometacarp.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 944.53 kB
Formato Adobe PDF
944.53 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/698723
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact